SAFETY INFORMATION
Continued
15. Turn off and unplug heater and let
cool before servicing. Only a
qualified service person should
service and repair heater.
16. Operating heater above elevations
of 4,500 feet could cause pilot
outage.
17. Do not operate heater if any log is
broken. Do not operate heater if any
log is chipped (dime-sized or
larger).
18. To prevent performance problems,
do not use propane/LP fuel tank of
less than 100 lbs. capacity.
State of Massachusetts:
installation must be made by a li-
censed plumber or gas fitter in the
Commonwealth of Massachusetts.
Sellers of unvented propane or natu-
ral gas-fired supplemental room heat-
ers shall provide to each purchaser a
copy of 527 CMR 30 upon sale of the
unit.
In the state of Massachusetts,
unvented propane or nature gas-fired
space heaters shall be prohibited in
bedrooms and bathrooms.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
Water vapor is a by-product of gas cmbustin. An unvented room heater produces approximately one(1) ounce
(30ml) of water for every 1,000 BTU's(.3KW's)of gas input per hour.
Unvented room heaters are recommended as supplemental heater(a room). Rather than a primary heat source
(an entire house). In most supplemental heat applications, the water vapor does not creat a problem. In most
applications,the water vapor enhances the low humidity atmosphere experienced during cold weather.The following
steps will help insure that water vapor does not become a problem.
1.Be sure the heater is a sized properly for the application, including ample combustion air and circulation air.
2.If high humidity is experienced,dehumidifier may be used to help lower the water vapor content of the air.
3.Do not use an unvented room heater as the primary heat source.
PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an
Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS/pilot
is a required feature for vent-free
room heaters. The ODS/pilot shuts off
the heater if there is not enough
fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor.
This system requires no matches,
batteries, or other sources to light
heater.
LOCAL CODES
lnstall and use heater with care.
F o l l o w a l l l o c a l c o d e s . I n t h e
The
absence of local codes, use the
latest edition of The National Fuel
Gas Code, ANSZ 223.1, also known
as NFPA 54*.
PRODUCT IDENTIFICATION
Figure1- Vent Free LP/NG Gas Stove
3
*Available from:
American National Standards
lnstitute, lnc.
1430 Broadway
New York, NY 10018
National Fire Protection
Association, lnc.
Batterymarch Park
Quincy. MA 02269
This heater is designed for vent-free
operation. State and local codes in
some
areas prohibit the use of
vent-free heaters.
UNPACKING
1. Remove top inner pack.
2. Tilt carton so that stove is upright.
3. Remove protective side packaging.
4. Slide stove out of carton.
5. Remove protective plastic wrap.
6. Remove screen by lifting and then
pulling forward.
7. Remove log set by cutting plastic
ties.
8. Carefully unwrap log.
9. Check for any shipping damage. If
stove or log is damaged, promptly
inform dealer where you bought
stove.