Electrical Connections - Alto-Shaam HFM-24 Installation, Operation & Manintenance Manual

Hot food module electric
Hide thumbs Also See for HFM-24:
Table of Contents

Advertisement

WARNING
To prevent serious injury, death, or
property damage:
All electrical connections must be
made by a qualified and trained service
technician in accordance with applicable
electrical codes.
This appliance must be adequately
grounded in accordance with local
electrical codes or, in the absence of local
codes, with the current edition of the
National Electrical Code ANSI/NFPA No.
70. In Canada, all electrical connections
are to be made in accordance with CSA
C22.1, Canadian Electrical Code Part 1 or
local codes.
CE-approved appliances include an
equipotential-bonding terminal marked
with the symbol shown on the left .
Provisions for earthing are to be made in
accordance with IEC:2010 60335-1 section
27 or local codes.
1. An identification tag is permanently mounted on
the unit.
2. Plug the unit into a properly grounded receptacle ONLY,
positioning the unit so the power supply cord is easily
accessible in case of an emergency. Arcing will occur
when connecting or disconnecting the unit unless all
controls are in the OFF position.
MN-35698 • Rev 6 • 07/18 • HFM Series Merchandiser

Electrical Connections

WARNING
To prevent SERIOUS INJURY, DEATH or
PROPERTY DAMAGE:
All electrical connections must be made
by a qualified and trained service
technician in accordance with applicable
electrical codes.
CAUTION
Power source must match voltage identified
on appliance rating tag. The rating tag
provides essential technical information
required for any appliance installation,
maintenance or repairs. Do not remove,
damage or modify the rating tag.
Electrical
HFM-24
V
Ph
Hz
208
1
60
230
1
50/60
HFM-30
V
Ph
Hz
208
1
60
230
1
50/60
HFM-48
V
Ph
Hz
208
1
60
230
1
50/60
HFM-72
V
Ph
Hz
208
1
60
230
1
50/60
*Additional 230V plugs available
CH2-16P
Plug rated 250V
A
kW
NEMA 6-15P
3.2
0.65
15A, 250V plug
CEE 7/7*
3.4
0.78
Plug rated 250V
A
kW
NEMA 6-15P
2.8
0.62
15A, 250V plug
CEE 7/7*
3.4
0.83
Plug rated 250V
A
kW
NEMA 6-15P
6.4
1.3
15A, 250V plug
CEE 7/7*
7.1
1.6
Plug rated 250V
A
kW
NEMA 6-15P
9.7
1.99
15A, 250V plug
CEE 7/7*
10.6
2.4
Plug rated 250V
BS1363
Plug rated 250V
11