E L E C T R I C A L C O N N E C T I O N
The appliance must be installed by a qualified service
technician. The oven must be properly grounded in
accordance with the National Electrical Code and
applicable local codes.
D A N G E R
This appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence
of local codes, with the current
edition of the National Electrical
Code ANSI/NFPA No. 70. In
Canada, all electrical connections
are to be made in accordance with
CSA C22.1, Canadian Electrical
Code Part 1 or local codes.
Failure to observe this precaution
may damage the appliance, result
in electrical shock, fire or personal
injury.
Plug the unit into a properly grounded receptacle ONLY,
positioning the unit so that the plug is easily accessible in
case of an emergency. Arcing will occur when connecting
or disconnecting the unit unless all controls are in the
"
" position.
off
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
After wiring and power connection has been completed,
turn the main power switch to the "
main power switch can be left "
should be turned "
" when cleaning or performing
off
maintenance or repairs to the rotisserie.
" WARNING " R I SK O F F I RE !
Use a UL Listed grounding type plug rated 250 Volts,
50 Amperes, 1 Phase, 3 wire for single phase units and
250 V, 50 A, 3 Phase, 4 wire for three phase units. Plug
to be selected and installed only by qualified service
personnel. Individual conductors are marked L
when applicable, N when applicable, and G.
D A N G E R
Appliances with no cord provided
by factory must be equipped with a
cord of sufficient length to permit the
appliance to be moved for cleaning.
Electrical connections must be made
by a qualified service technician in
accordance with applicable electrical
codes. Use the correct AWG wire size
based on the electrical requirements
for the appliance.
Failure to observe this precaution
may result in electrical shock,
damage to the appliance, fire,
property damage or personal injury.
" position. The
on
" for daily use, but
on
, L
, L
1
2
3
M N-28 657 (Re v 1 ) 03/15 • AR- 7E Ro ti ss eri e • 5
I N S T A L L A T I O N
E LE C TR IC AL
VOLTAGE
PHASE
CYCLE
208
1
60
240
1
60
208
3
60
240
3
60
380-415
3
50/60
380
3
50/60
415
3
50/60
Wire diagrams are located in the inside access panel of the unit.
R EGARDING INTER NATIONAL STANDARD UNITS:
If the unit is not equipped with flexible cord with plug, an
all-pole country approved disconnection device which has
a contact separation of at least 3mm in all poles must be
incorporated in the fixed wiring for disconnection. When
using a cord without a plug, the green/yellow conductor
shall be connected to the terminal which is marked with the
ground symbol. If a plug is used, the socket outlet must be
easily accessible. If the power cord needs replacement, use
a similar one obtained from the distributor.
For CE approved units: To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity,
an equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances/metal parts
to provide sufficient protection against potential
difference. The terminal is marked with
the following symbol.
Power Cord Connection: The side connection
is recommended for all applications. If a bottom
connection is necessary for counter top units, user
will need to provide a cutout in the countertop to
allow the cord to hang freely without crimping.
Hard wired models:
Hard wired models must be equipped with a country
certified external allpole disconnection switch with
sufficient contact separation.
If a power cord is used for the connection of the product an
oil resistant cord like H05RN or H07RN or equivalent must
be used.
NOTE:
Where local codes and CE regulatory
requirements apply, appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
D A N G E R
Ensure power source matches
voltage identified on appliance rating
tag. The rating tag provides essential
technical information required for any
appliance installation, maintenance
or repairs. Do not remove, damage or
modify the rating tag.
/
kW
HZ
AMPS
40.0
8.3
BARE END
38.0
8.8
BARE END
33.0/ph
8.3
BARE END
32.0/ph
8.8
BARE END
24.0/ph
8.8
22.0/ph
7.4
24.0/ph
8.8
,
NO PLUG
,
NO PLUG
,
NO PLUG
,
NO PLUG
NO CORD
NO PLUG