ELECTRICAL CONNECTION

1. An identification tag is permanently mounted
on the unit.
2. If necessary, a proper receptacle or permanent
wiring for this unit must be installed by a
licensed electrician in accordance with
applicable local electrical codes.
3. Plug the unit into a properly grounded
receptacle ONLY, positioning the unit so the
power supply cord is easily accessible in case
of an emergency. Arcing will occur when
connecting or disconnecting the unit unless
all controls are in the OFF position.
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
ELECTRICAL
I N S T A L L A T I O N
/
VOLTAGE PHASE CYCLE
HZ
120
1
50/60
230
1
50/60
120
1
50/60
230
1
50/60
# 8 7 5 • I N S TA L L AT I O N / O P E R AT I O N / S E RV I C E M A N U A L • 5.
230V: To prevent an electrical shock hazard
between the appliance and other appliances or
metal parts in close vicinity, an equalization-
bonding stud is provided. An equalization
bonding lead must be connected to this stud
and the other appliances / metal parts to
provide sufficient protection against potential
difference. The terminal is marked with the
following symbol.
NOTE: The appliance must be connected
to an electrical circuit that is protected
by an external GFCI outlet.
kW
AMPS
12.0
1.4
5.5
1.15
16.0
1.9
8.5
1.95
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70.
In Canada, all
electrical connections are to be made
in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
5-20
NEMA
P
20A-125
V PLUG
6-20
NEMA
P
20A-250
V PLUG
5-20
NEMA
P
20A-125
V PLUG
6-20
NEMA
P
20A-250
V PLUG