Mounting Tensile Strain Relief - Siemens SCALANCE XF-200BA Operating Instructions Manual

Simatic net industrial ethernet switches
Hide thumbs Also See for SCALANCE XF-200BA:
Table of Contents

Advertisement

5. Screw the bus adapter to the BaseUnit of the device with the supplied screw (tightening
torque 0.2 Nm)
Use the specified tool for this.
6. Insert the connection plugs into the sockets intended for this on the bus adapter.
Removal
To remove a bus adapter, follow the steps below:
1. Turn off the power to the device.
2. Remove all connected cables from the BusAdapter.
3. Loosen the screw connection of the bus adapter.
4. Pull the bus adapter out of the Base Unit to the front.
5. If necessary remove the strain relief, see section "Mounting tensile strain relief (Page 37)".
6. Close the bus adapter slot with a cover.
4.4

Mounting tensile strain relief

Required tools
● Torx screwdriver, size T10
● Cable ties
We recommend cable ties with a width of 4.8 mm. The maximum width is 7.0 mm. The
length of the cable tie is min. 60 mm.
Installation
Figure 4-4
SCALANCE XF-200BA
Operating Instructions, 09/2018, C79000-G8976-C470-03
.
Mounting tensile strain relief
Installation
4.4 Mounting tensile strain relief
37