SIMATIC NET
Industrial Ethernet switches
SCALANCE XR-100WG
Operating Instructions
09/2020
C79000-G8976-C455-04
Introduction
Safety notices
Description of the device
Installation
Connecting up
Upkeep and maintenance
Technical specifications
Dimension drawings
Approvals
1
2
3
4
5
6
7
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE XR-100WG

  • Page 1 Introduction Safety notices Description of the device SIMATIC NET Installation Industrial Ethernet switches SCALANCE XR-100WG Connecting up Upkeep and maintenance Operating Instructions Technical specifications Dimension drawings Approvals 09/2020 C79000-G8976-C455-04...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Introduction

    These operating instructions apply to the following devices: • SCALANCE XR108-2PoE WG • SCALANCE XR124WG Unless mentioned otherwise, the descriptions in these operating instructions refer to all devices of the SCALANCE XR-100WG product group named above in the section on validity. Designations used Classification Description...
  • Page 4 The DVD ships with certain SIMATIC NET products. • On the Internet under the following address: 50305045 (https://support.industry.siemens.com/cs/ww/en/view/50305045) Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 5 (https://www.siemens.com/industrialsecurity) Catalogs You will find the article numbers for the Siemens products of relevance here in the following catalogs: • SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI • SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 •...
  • Page 6 Introduction Trademarks The following and possibly other names not identified by the registered trademark sign ® registered trademarks of Siemens AG: SIMATIC NET, SCALANCE, C-PLUG, OLM SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 7: Table Of Contents

    Safety when connecting up....................31 Industrial Ethernet ......................33 4.2.1 Electrical..........................33 4.2.2 Optical..........................34 Wiring rules ........................35 24 VDC power supply......................35 Power supply 240 VAC ....................... 36 Functional ground ......................38 SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 8 Technical specifications of the SCALANCE XR124WG (240 VAC variant) ....... 45 Cable lengths........................46 Switching properties ......................46 Mechanical stability (in operation) ..................47 Dimension drawings ..........................49 Approvals ............................. 51 FDA and IEC XR-100WG marks.................... 58 Index ..............................61 SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 9: Safety Notices

    This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only. This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 10 Safety notices SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 11: Description Of The Device

    The following components are supplied with a SCALANCE XR-100WG: • One device • Two 2-terminal blocks for the power supply 24 V DC The following parts are included in the scope of delivery of a SCALANCE XR-100WG with plug-in transceiver slots: • 1 cover per pluggable transceiver slot...
  • Page 12: Device Views

    The following figure shows an overview of the components of a 24 VDC variant of a SCALANCE XR124WG. ① Grounding screw ② Electrical ports with port LEDs ③ Integrated brackets for 19" rack mounting ④ 24 VDC power supply ⑤ LED "L for the power supplies SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 13: 240 V Ac Variant

    Grounding bolts (rear) ⑥ LED display • The "F" LED for faults • LED "OVERLOAD" for PoE use • LED "L for the power supplies Accessories The following accessories are available for SCALANCE XR-100WG: SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 14 1 x 1000 Mbps LC port optical for glass FO cable 6GK5 992-1AQ00-8AA0 (single mode) up to max. 120 km Pluggable transceivers with the supplement (C) in the type name have varnished printed circuit boards (conformal coating). SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 15 • If you use bidirectional pluggable transceivers, the maximum ambient temperature is reduced to 50 ℃. For the values of the ambient temperature without pluggable transceivers, refer to the section "Technical specifications (Page 43)". SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 16: Led Display

    LED color LED status Meaning The device has detected a problem. Possible errors/faults: • Internal power supply error • Short-circuit at power supply The device is switched off or has not detected a problem. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 17: Overload" Led

    No link exists Power over Ethernet Function The "Power over Ethernet" function supplies connected devices with power via the Ethernet cable. Devices supplied with power via an Ethernet cable do not require a separate voltage source. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 18: Power And Voltage Range According To The Standard

    • The electrical isolation of the ports is designed for 1500 Vrms (1 minute). • Ports P1 to P8 support PoE classes 0 to 6. They supply connected devices with up to 60 W per port (according to IEEE802.3af, IEEE802.3at and IEEE802.3bt). SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 19: Voltage Transmission And Pin Assignment (Ports P1 To P8)

    Pin 2 Positive power supply Pin 3 Negative power supply Pin 4 Positive power supply Pin 5 Positive power supply Pin 6 Negative power supply Pin 7 Negative power supply Pin 8 Negative power supply SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 20 Description of the device 2.5 Power over Ethernet SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 21: Installation

    Replacing components may impair suitability for Class 1, Division 2 or Zone 2. WARNING The device is intended for indoor use only. WARNING The device may only be operated in an environment with pollution degree 1 or 2 (see IEC 60664-1). SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 22 Substitution of components may impair suitability for Division 2. WARNING Do not remove or replace while circuit is live when a flammable or combustible atmosphere is present. WARNING Explosion hazard Do not disconnect equipment when a flammable or combustible atmosphere is present. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 23 If you use components and accessories that are not approved for SIMATIC NET devices or their target systems, this may violate the requirements and regulations for safety and electromagnetic compatibility. Only use components approved for the SIMATIC NET devices. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 24: Types Of Installation

    Mounting CAUTION Risk of injury if subjected to irregular mechanical strain The device must be mounted in the 19" rack so that even if there is irregular mechanical strain, no dangerous situation can result. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 25 E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e. g. use of power strips). SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 26: Din Rail Mounting / Wall Mounting

    DIN rail mounting / wall mounting Installation DIN rail mounting and wall mounting are described in this section, because a DIN rail is required also for wall mounting. Note that PoE variants have a different guide rail. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 27 1. In the recess on the top of the housing, there are two guides for receiving a DIN rail. Push the DIN rail into the guides as shown in the following figure: Figure 3-2 Connecting SCALANCE and DIN rail SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 28 2. Screw the protruding ends of the DIN rail to the wall or other surface for attaching the DIN rail. Screwing in the DIN rail Screwing on the standard mounting rail for PoE variants 3. Connect the cables, see section "Connecting up (Page 31)" SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 29: Inserting And Removing Pluggable Transceivers

    WARNING Use only approved SFP transceivers If you use SFP transceivers that have not been approved by Siemens AG, there is no guarantee that the device will function according to its specifications. If you use unapproved SFP transceivers, this can lead to the following problems: •...
  • Page 30: Removing A Pluggable Transceiver (Sfp)

    3. Remove the pluggable transceiver from the pluggable transceiver slot. Note Do not use force It must be possible to remove the pluggable transceiver easily and without applying any force. 4. Close the pluggable transceiver slot with a sealing plug. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 31: Connecting Up

    Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not connect or disconnect cables to or from the device when a flammable or combustible atmosphere is present. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 32 The LAN is designed either for “Environment A” according to IEEE802.3 or "Environment 0" according to IEC TR 62102. Do not connect any electrical connectors directly to the telephone network (telephone network voltage) or a WAN (Wide Area Network). SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 33: Industrial Ethernet

    Please note that the direct connection of two ports on the IE switch or accidental connection over several IE switches causes an illegal loop. Such a loop can lead to network overload and network failures. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 34: Optical

    • Close unused optical sockets and plugs as well as pluggable transceivers and slots with the supplied protective caps. LC connector technology The attachment to Industrial Ethernet uses LC connector technology (Lucent Connector). Pluggable transceiver slot/ plugged in transceiver SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 35: Wiring Rules

    These can result, for example, due to lightning or switching of large inductive loads. One of the tests used to attest the immunity of the SCALANCE XR-100WG to electromagnetic interference is the "surge immunity test" according to EN 61000-4-5. This test requires overvoltage protection for the power supply lines.
  • Page 36: Power Supply 240 Vac

    • The power supply is connected over a high resistance with the enclosure to allow an ungrounded set up. The two power inputs are non-floating. • Note the wiring rules. Position and assignment Figure 4-1 Position of the terminal block on a SCALANCE XR-100WG Contact Assignment Contact Assignment...
  • Page 37 • The power supply is single (1 x 240 VAC). • To connect the power supply, use the power cable listed in the section "Accessories (Page 13)". Position Figure 4-2 Position of the device installation connector SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 38: Functional Ground

    DIN rail terminal. To connect the functional ground, use a copper cable of category 20 AWG or a cable with a cross- section ≥ 0.75 mm SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 39 To connect the functional grounding for devices with a grounding bolt, proceed as follows: ① ② ③ 1. Put the parts together on the grounding bolt as shown in the drawing. ④ 2. Tighten the nut with a maximum tightening torque of 1.5 Nm. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 40 With automation components, functional ground also ensures interference-free operation of a controller. Via the functional ground, interference currents coupled in via the connecting cables are discharged to ground. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 41: Upkeep And Maintenance

    If the power supply is too low, then the internal power supply will switch off causing the "L" LED and all port LEDs to go off. The functionality of the SCALANCE XR-100WG is no longer available. For correct operation, a power supply of at least 19.2 V for 24 V DC versions or 85 V for 240 V AC versions is required.
  • Page 42 Upkeep and maintenance SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 43: Technical Specifications

    During operation at 25 ℃ ≤ 95% without condensation Housing, dimensions and weight Design Rack Housing material Metal Degree of protection IP30 Dimensions (W x H x D) 482.6 x 43.6 x 133 mm Weight 2900 g SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 44: Technical Specifications Of The Scalance Xr124Wg (24 Vdc Variant)

    During operation at 25 ℃ ≤ 95% without condensation Housing, dimensions and weight Design Rack Housing material Metal Degree of protection IP30 Dimensions (W x H x D) 482.6 x 43.6 x 127 mm Weight 2700 g SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 45: Technical Specifications Of The Scalance Xr124Wg (240 Vac Variant)

    During operation at 25 ℃ ≤ 95% without condensation Housing, dimensions and weight Design Rack Housing material Metal Degree of protection IP30 Dimensions (W x H x D) 482.6 x 43.6 x 177 mm Weight 3300 g SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 46: Cable Lengths

    Wall mounting Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) > 76 years Cable lengths The following technical specifications apply to SCALANCE XR-100WG. Cable Permitted cable length IE TP torsion cable 0 to 45 m with IE FC Outlet RJ-45 + 10 m TP cord...
  • Page 47: Mechanical Stability (In Operation)

    Note The number of SCALANCE XR-100WG modules connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XR-100WG product line, it is delayed by the store and forward function of the device: •...
  • Page 48 Technical specifications 6.6 Mechanical stability (in operation) SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 49: Dimension Drawings

    Front view of the SCALANCE XR-100WG Figure 7-1 Width and height based on the example of a 24 V DC variant SCALANCE XR-100WG 24 VDC variant view from above Figure 7-2 Depth SCALANCE XR-100WG 240 VAC variant view from above...
  • Page 50 Dimension drawings Top view for SCALANCE XR-100WG PoE variant Figure 7-4 Depth SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 51: Approvals

    Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15273/cert). Notes for the manufacturers of machines The devices are not machines in the sense of the EC Machinery Directive.
  • Page 52 EC L174, 01/07/2011, p. 88-110 You will find the EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15273/ cert).
  • Page 53 • On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection • On the Internet pages of Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/view/78381013) The SIMATIC NET products described in these operating instructions meet the requirements of the EU directive 2014/34/EU "Equipment and Protective Devices for Use in Potentially Explosive...
  • Page 54 Type of protection of the device The devices are approved for various types of protection. You can find the type of protection of your device and the IECEx certificate number on the nameplate. Permitted types of protection SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 55 The device contains optical radiation sources which comply with the limits of Class 1 according to IEC 60825-1. Fiber-optic cables connected to these optical radiation sources may therefore be routed either to or through hazardous areas requiring Category 2G, 3G, 2D or 3D equipment. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 56 Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 Note Only variants with 24 VDC power supply meet the requirements of this approval. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 57 Cl. 1, Zone 2, GP IIC T4 Report no. E240480 Note Only variants with 24 VDC power supply meet the requirements of this approval. Note for Australia - RCM The product meets the requirements of the RCM standard. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 58: Fda And Iec Xr-100Wg Marks

    * In modular devices, you can find the marking on the plug-in transceiver used or in the relevant operating instructions. CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 59 The test was performed with a device and a connected communications partner that also meets the requirements of the standards listed above. When operating the device with a communications partner that does not comply with these standards, adherence to the corresponding values cannot be guaranteed. SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 60 Approvals A.1 FDA and IEC XR-100WG marks SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 61: Index

    Fault LED, 16 Plug-in transceiver Functional ground, 38 SFP bidirectional, 15 PoE, 17 Port LED, 12, 13, 17 Power cable, 13, 37, 38 Glossary, 4 Power over Ethernet, 17 Grounding screw, 12, 13, 39 SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...
  • Page 62 Sealing plug, 29, 30 SFP transceiver, 14 SFP+ transceiver, 16 SIMATIC NET glossary, 4 SIMATIC NET manual, 4 Slot, 29 System manual, 4, 24, 59 Wall mounting, 26 Weight, 43, 44, 45 Wiring, 35 SCALANCE XR-100WG Operating Instructions, 09/2020, C79000-G8976-C455-04...