Removal
Figure 4-2
To remove the device from a DIN rail, follow the steps below:
1. Disconnect all connected cables.
2. Release the DIN rail locking mechanism by pressing down on the release button
3. Pull the lower part of the device away from the DIN rail
4.3

Mounting bus adapters

NOTICE
Do not install or uninstall a bus adapter during operation
A bus adapter may only be installed or uninstalled if the device is turned off.
If you install a bus adapter during operation it will not be recognized by the device.
If you uninstall a bus adapter during operation the device will react as follows:
● The bus adapter slot will be deactivated.
● The red fault LED "F" lights up.
● The event is shown in the log and error table.
To reactivate the bus adapter slot, restart the device:
● The bus adapter slot is active.
● The red fault LED "F" goes off.
SCALANCE XF-200BA