Connecting up
5.6 Grounding
Signaling faults
● The signaling of errors by the signaling contact is synchronized with the fault LED "F", see
section ""F" LED (Page 25)".
All errors that the fault LED "F" indicates (freely configurable) are also signaled by the
signaling contact.
● If an internal fault occurs, the fault LED "F" lights up and the signaling contact opens.
● If you connect a communications node to an unmonitored port or disconnect it, this does
not cause an error message.
● The signaling contact remains open until the error has been eliminated.
5.6
Grounding
The device is grounded over the DIN rail.
46
Operating Instructions, 09/2018, C79000-G8976-C470-03
SCALANCE XF-200BA