The derating values depend on the maximum ambient temperatures. For the bus adapters
with the following maximum ambient temperatures the corresponding derating values apply.
Maximum ambient temperature during opera‐
tion up to 2000 m
‑40 °C to +60 ℃
‑40 °C to +50 ℃
7.2

Cable lengths

Copper cable
Cable
IE TP torsion cable
with IE FC Outlet RJ-45 + 10 m TP cord
IE TP torsion cable
with IE FC RJ-45 Plug 180
IE FC TP Marine / Trailing / Flexible cable
with IE FC Outlet RJ-45 + 10 m TP cord
IE FC TP Marine / Trailing / Flexible cable
with IE FC RJ-45 Plug 180
IE FC TP standard cable
with IE FC Outlet RJ-45 + 10 m TP cord
IE FC TP standard cable
with IE FC RJ-45 Plug 180
Fiber-optic cable
Cable
980/1000 plastic optical fi‐
ber
200/230 polymer cladded
fiber
7.3

Switching properties

Switching properties
Aging time
Maximum frame size
SCALANCE XF-200BA
Operating Instructions, 09/2018, C79000-G8976-C470-03
Permitted cable length
0 to 50 m
0 to 100 m
Can be configured (default value: 30 seconds)
1632
Derating
up to 3000 m
‑40 °C to +55 ℃
up to 4000 m
‑40 °C to +51 ℃
up to 3000 m
‑40 °C to +44 ℃
up to 4000 m
‑40 °C to +40 ℃
Permitted cable length
0 to 45 m
+ 10 m TP cord
0 to 55 m
0 to 75 m
+ 10 m TP cord
0 to 85 m
0 to 90 m
+ 10 m TP cord
0 to 100 m
Attenuation
9 dB max. permitted FO cable attenuation with
3 dB link power margin
6 dB max. permitted FO cable attenuation with
3 dB link power margin
Technical specifications
7.3 Switching properties