4.7

Mounting bus adapters

Required tool:
● Slotted screwdriver, blade width 3 to 3.5 mm
or
● Torx screwdriver, size T10
Installation
Figure 4-5
To fit a bus adapter, follow the steps below:
1. Plug the bus adapter parallel into the BaseUnit until it can be heard to lock in place.
2. Screw the bus adapter to the BaseUnit of the device with the included screw (tightening
torque 0.2 Nm).
To do this, use a screwdriver with a 3 to 3.5 mm blade.
3. Insert the connection plugs into the sockets intended for this on the bus adapter.
Removal
To remove a bus adapter, follow the steps below:
1. First disconnect all connected cables.
2. Loosen the screw connection of the bus adapter.
3. Pull the bus adapter out of the Base Unit to the front.
SCALANCE X-200
Operating Instructions, 02/2018, C79000-G8976-C284-12
Mounting bus adapters
Installation
4.7 Mounting bus adapters