Figure 13: Wiring For Installation Using The Ademco Ab-12 Bell/Housing - Bosch D9412G Operations & Installation Manual

Table of Contents

Advertisement

D9412G/D7412G | Operation & Installation Guide |

Figure 13: Wiring for Installation Using the Ademco AB-12 Bell/Housing

1 2 3 4 5 6
1
2
3
4
Bosch Security Systems | 10/03 | 43488E
7.0 On-Board Points
43489G
LEDs Off When Normal
Charging Status
YEL
Low Battery - 12.1 VDC
RED
Reference D9412G/D7412G Approved Application Compliance Guide (P/N:43494___)
10.2 VDC - Battery Load Shed
Reference D9000/D9000G Series Technogram (P/N:33284___)
CLASS 2 TRANSFORMER
The Power Supply Provides a Maximum of 1.4 Amps For The Control Panel and All
1
16.5 VAC 40 VA 60 Hz
Accessory Devices. For System Loading, See D9412G/D7412G Operation and Installation
Model D1640
Guide (P/N:43488___).
Internally Fused - Do Not short
All External Connections Except Terminal 5 (Battery Positive) Are Inherently Power
Requires Unswitched Outlet
2
Limited. Requirements For Battery Standby Time May Reduce Allowable Output.
Do Not Share With Other Equipment
CAUTION:
See D9412G/D7412G Operation and Installation Guide (P/N:43488)
+ AUX POWER
3
For Power Requirements Relating to Terminals 6
WARNING!
BATTERY NEGATIVE ONLY
4
Multi-Battery Installation Requires
Maximum Charging
Model D122 Dual Battery Harness.
Current 1.4 Amps.
Improper Installation Can Be a Fire
5
BATTERY POSITIVE ONLY
Hazard.
PROGRAMMABLE
This equipment should be installed in accordance with the NFPA 70 (National Electrical Code)
RELAY A
6
ALARM OUTPUTS
and NFPA 72 (National Fire Alarm Code) for Local, Central Station, Remote Station and Household Fire
Terminals
Warning Systems and under the limits of the Local Authority Having Jurisdiction (National Fire
7
8
&
Protection Association, Batterymarch Park, Quincy, MA 02269) Printed information describing proper
RELAY B
7
installation, operation, testing, maintenance, evacuation planning and repair service is to be provided
Requires Optional
with this equipment.
Model D136 Relay
In ALT ALARM
RELAY C
8
D9412G Control / Communicator is UL Listed For Central Station, Local, Remote Station and Household
& SW AUX
Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm.
System is Intended To Be Checked By A Qualified Technician At Least Every 3 Years.
9
COMMON
The types of initiating circuits the panel has been approved for are A, M, W, SS.
10
EARTH GROUND
GROUND FAULT DETECT
Point 1 Point 2
Enabled
Disabled
PHONE MONITOR SELECT
LOOP START
GND START
GROUND START
PHONE
Requires Relay
RED
LED
Model D136 in
11
12
13
ON WHEN
Ground
COMMUNICATING
Start Socket
OFF WHEN IDLE
5
Digital Alarm Communicator Transmitter
For System Wiring Diagram, Issue A
For Compatible Smoke Detectors
POWER SUPPLY REQUIREMENTS
7
Battery: Replace Every 3 to
5 years with Model D126, 12 V
7 Amp Hr Lead Acid Battery
VOLTAGE RANGES
Open
3.7 - 5.0 VDC
Normal
2.0 - 3.0 VDC
Short
0.0 - 1.3 VDC
Point 3 Point 4
Point 5 Point 6
Point 7 Point 8
14
15
16
17
18
19
20
21
22
1 - Bell
2 - Inner bell box lining
3 - Outer bell box
4 - Bell tampers
5 - 220 k Ω 0.5 W EOL
Reset Pin
Disable All Except Battery
Charging And Programming
PERIPHERAL DEVICE CONNECTIONS
32
RED
POWER +
YELLOW
DATA BUS A
31
30
GREEN
DATA BUS B
29
BLACK
COMMON
N.F.P.A.
28
ZONEX OUT 1
Style 3.5
Signaling
Line
27
Circuits
ZONEX IN 1
26
ZONEX OUT 2
25
ZONEX IN 2
24
ZONEX POWER +
23
ZONEX COMMON
Point 8
PROG
GND FAULT
CONN
Detect
D
E
I
N
S
A
A
B
B
L
L
GRN
E
E
EN | 35