Overview; 9000G Series Panel Differences; Figure 1: System Configuration; Table 4: 9000G Series Panel Differences - Bosch D9412G Operations & Installation Manual

Table of Contents

Advertisement

D9412G/D7412G | Operation & Installation Guide |
2.0

Overview

Figure 1: System Configuration

Each D8128D OctoPOPIT combines
eight POPIT points in one module.
D8125 or D8125MUX Interface
used for point expansion.
Use command centers and/or keyswitches to arm the
panel by area. Each panel can have up to eight areas.
Each area can have its own account number or areas
can be grouped together with a common account
number. Points of protection are assigned to areas.
2.1

9000G Series Panel Differences

Table 4 provides an overview of the differences between
the D9412G, D7412G, and D7212G Control Panels.
Bosch Security Systems | 10/03 | 43488E
2.0 Overview
D9210B Modules may be
used for access control.
Control
On-Board Points
D8129 OctoRelay provides alarm
and auxilliary relay output.
(Other functions available.)
D9133TTL-E allows communciation
over a Local or Wide Area Network
(LAN/WAN).
Panel
D928 Module allows the panel
to monitor two phonelines.
1 to 8
D8132 Modules (two 12 VDC, 7Ah batteries)
provide additional power for command
centers and other powered devices.
D9131A Module connects
to a parallel printer to print
the event log.

Table 4: 9000G Series Panel Differences

New Features
Access Control
Expanded Users
Arm/Disarm Passcodes
Cards/Tokens
Passcode-Protected
Custom Functions
Number of Printers
Number of Points
Number of Relays
EN | 11
D9412G
D7412G
D7212G
Yes
Yes
No
8 doors
2 doors
249
99
99
996
396
N/A
16
4
4
3
1
1
246
75
40
128
64
24

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412g

Table of Contents