D9412G/D7412G | Operation & Installation Guide |
A.2
D9412G Control Panel, 3 of 3

Figure 36: D9412G System Wiring Diagram, 3 of 3

43489G
LEDs Off When Normal
YEL
Charging Status
Low Battery - 12.1 VDC
RED
Reference D9412G/D7412G Approved Application Compliance Guide (P/N:43494___)
10.2 VDC - Battery Load Shed
CLASS 2 TRANSFORMER
The Power Supply Provides a Maximum of 1.4 Amps For The Control Panel and All
1
16.5 VAC 40 VA 60 Hz
Accessory Devices. For System Loading, See D9412G/D7412G Operation and Installation
Model D1640
Guide (P/N:43488___).
Internally Fused - Do Not short
All External Connections Except Terminal 5 (Battery Positive) Are Inherently Power
Requires Unswitched Outlet
2
Do Not Share With Other Equipment
Limited. Requirements For Battery Standby Time May Reduce Allowable Output.
CAUTION:
+ AUX POWER
3
WARNING!
BATTERY NEGATIVE ONLY
4
Multi-Battery Installation Requires
Maximum Charging
Model D122 Dual Battery Harness.
Current 1.4 Amps.
Improper Installation Can Be a Fire
BATTERY POSITIVE ONLY
5
Hazard.
PROGRAMMABLE
This equipment should be installed in accordance with the NFPA 70 (National Electrical Code)
RELAY A
6
ALARM OUTPUTS
and NFPA 72 (National Fire Alarm Code) for Local, Central Station, Remote Station and Household Fire
Terminals
Warning Systems and under the limits of the Local Authority Having Jurisdiction (National Fire
7
&
8
Protection Association, Batterymarch Park, Quincy, MA 02269) Printed information describing proper
RELAY B
7
installation, operation, testing, maintenance, evacuation planning and repair service is to be provided
Requires Optional
with this equipment.
Model D136 Relay
In ALT ALARM
8
RELAY C
& SW AUX
D9412G Control / Communicator is UL Listed For Central Station, Local, Remote Station and Household
9
COMMON
10
EARTH GROUND
GROUND FAULT DETECT
Enabled
Disabled
PHONE MONITOR SELECT
LOOP START
GND START
GROUND START
PHONE
R ED
Requires Relay
LED
Model D136 in
11
ON WHEN
Ground
COMMUNICATING
Start Socket
OFF WHEN IDLE
D8125
5
-
+
7
Note: All external connections except Terminal 5
(battery positive) are inherently power limited.
Bosch Security Systems | 10/03 | 43488E
Digital Alarm Communicator Transmitter
Reset Pin
For System Wiring Diagram, Issue A
Disable All Except Battery
Charging And Programming
Reference D9000/D9000G Series Technogram (P/N:33284___)
For Compatible Smoke Detectors
PERIPHERAL DEVICE CONNECTIONS
POWER SUPPLY REQUIREMENTS
RED
POWER +
YELLOW
DATA BUS A
See D9412G/D7412G Operation and Installation Guide (P/N:43488)
GREEN
DATA BUS B
For Power Requirements Relating to Terminals 6
7
Battery: Replace Every 3 to
BLACK
COMMON
5 years with Model D126, 12 V
7 Amp Hr Lead Acid Battery
N.F.P.A.
ZONEX OUT 1
Style 3.5
Signaling
Line
Circuits
ZONEX IN 1
ZONEX OUT 2
ZONEX IN 2
Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm.
System is Intended To Be Checked By A Qualified Technician At Least Every 3 Years.
ZONEX POWER +
The types of initiating circuits the panel has been approved for are A, M, W, SS.
VOLTAGE RANGES
Open
3.7 - 5.0 VDC
ZONEX COMMON
Normal 2.0 - 3.0 VDC
Short
0.0 - 1.3 VDC
Point 1 Point 2
Point 3 Point 4
Point 5 Point 6
Point 7 Point 8
Point 8
GND FAULT
Detect
D
E
I
N
S
A
A
B
B
L
12
13
14
15
16
17
18
19
20
21
22
L
GRN
E
E
D8125
6
-
+
7
Appendix A
D1255
32
3
31
3
30
3
29
3
28
3
27
3
26
3
25
3
24
3
23
4
PROG
CONN
1 - Up to 8 supervised
2 - Up to 3 supervised
3 - Power limited, supervised
4 - Power limited
5 - POPEX #1
6 - POPEX #2
7 - Up to 119 D9127U/T POPITs or up to 63 D8127U/T
POPITs.
8 - Zx 1: 15 D8128Ds
9 - Zx 2: 15 D8128Ds
10 - Zx 1: Up to 8 maximum
11 - Zx 2: Up to 8 maximum
D1256
D1257
1
D9210B
1
D8128D
8
D8128D
9
D8129
10
D8129
11
EN | 67
D1260
D9131A
2
D9133TTL-E

Hide quick links: