Compatible Accessories; New Features In D9412G/D7412G; Introduction; Ground Fault Detect - Bosch D9412G Operations & Installation Manual

Table of Contents

Advertisement

D9412G/D7412G | Operation & Installation Guide |
2.2. 1

Compatible Accessories

See the Bosch Security Systems Product Catalog for
additional information.

Table 6: Compatible Accessories

Model
Title
D122
Dual Battery Harness
D125B
Powered Loop Interface Module
D127
Reversing Relay
D129
Dual Class A Initiation Circuit Module
D130
Relay Module
D136
Plug-In Relay
D161
Phone Cord
D162
Phone Cord
D185
Reverse Polarity Module
D192C/D192G
Bell Circuit Supervision Module
D268/D269
Independent Zone Control (On-Board
and OctoPOPIT Points)
D279A
Independent Zone Control (On-Board
and OctoPOPIT Points)
D442
Bells (4 cm/10 in.)
D448/D449
Mini-Horns
D720
Command Center (Area LED)
D720R
LED Command Center (red)
D720W
LED Command Center (white)
D928
Dual Phone Line Switcher
D1218
12 V, 17.2 Ah Rechargeable Battery
D1255
Command Center (General Purpose)
D1255R
LED Command Center (red)
D1255RW
LED Command Center (white)
D1256
Fire Command Center
2.3

New Features in D9412G/D7412G

2.3. 1

Introduction

Eventually, the D9412G will replace the D9412 and
D9112, and the D7412G will replace the D7412 and
D7212. The suffix "G" indicates the control panel's
ability to detect ground fault conditions. All other
software feature sets that were available in the 9000
Series Control Panels remain the same as in the
D9412G/D7412G.
2.3.2

Ground Fault Detect

For the D9412G/D7412G to detect ground fault
conditions, the Earth Ground Terminal on the control
panels were electrically isolated from all other
terminals. A Ground Fault Detect Enable switch (S4)
was added to the panel and is located just under
Bosch Security Systems | 10/03 | 43488E
2.0 Overview
Model
D1257
D1260
D1640
D5500
D8004
D8124A, D8122
Derived Channel STU
D8125
D8125MUX
D8125INV*
D8128D
D8129
D8130
D8132
D9002-5
D9127U/T
D9131A
D9210B
ZX776Z
ZX794Z
ZX865
ZX938Z
ZX970
* The D8125INV has not been investigated by UL. Not to be
used in UL Listed installations.
Terminal 10, Earth Ground. See Section 3.5.2 Ground
Fault Detect Enable for information on operating this
function.
2.3.3
Added Feature When Using Ground Fault
Detect
When Ground Fault Detect is enabled (S4 closed), Points
1 to 8 can be used for non-powered fire-initiating
devices such as heat detectors, 4-wire smoke detectors,
pull stations, and so on. A D125B Powered Loop
Interface or a D129 Dual Class A Interface Module is no
longer required when connecting the non-powered
fire-initiating devices to Points 1 to 8.
Title
Fire Annunciator
Alpha V Command Center
16.5 VAC 40 VA Transformer
Remote Account Manager IV
Transformer Enclosure
POPEX Module
Multiplex Bus Interface
Wireless Interface Module
OctoPOPIT Module
OctoRelay Module
Release Module
Battery Charger Module
Accessory Module Mounting Skirt
POPIT Module
Parallel Printer Interface Module
Access Control Interface Module
PIR Motion Sensor (15 m/50 ft.) with POPIT
PIR Motion Sensor (24 m/80 ft.) with POPIT
PIR/Microwave Motion Sensor (1.7°C/35°F)
with POPIT
PIR Motion Sensor (18 m/60 ft.) with POPIT
PIR/Microwave Motion Sensor (1.7°C/35°F)
with POPIT
EN | 13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412g