8 Specify one or more tap ports. If you have an installed the optional PV-A-305-10G-UG I/O module,
the ports are eth4 and eth5. For each line, type the requested configuration information and press
[Enter].
======================================================================
Application Analytics Engine Network Configuration for Tap Mode
======================================================================
Enter the interface name for Tap Mode [eth1]:
Would you like to add another interface for Tap Mode (y/n) [n]? y
Enter the interface name for Tap Mode [eth2]:
Would you like to add another interface for Tap Mode (y/n) [n]? n
Proceed to step 10.
9 Specify one or more GRE tunnel interfaces. If you have an installed the optional PV-A-305-10G-UG
I/O module, the ports are eth4 and eth5. For each line, type the requested configuration information
and press [Enter].
======================================================================
Application Analytics Engine Network Configuration for Tunnel Interfaces
======================================================================
Enter the interface name for Tunnel Configuration [eth1]:
Enter information below to configure eth4
Enter the IP address for eth4 on pv88 [10.54.211.116]:
Enter the IP netmask [255.255.255.0]:
Enter the gateway address [10.54.211.1]:
Would you like to add another interface for Tunnel Configuration (y/n) [n]? y
Enter the interface name for Tunnel Configuration [eth1]:
Enter information below to configure eth5
Enter the IP address for eth5 on pv88 [10.54.222.117]:
Enter the IP netmask [255.255.255.0]:
Enter the gateway address [10.54.222.1]:
Would you like to add another interface for Tunnel Configuration (y/n) [n]? n
10 Enter the IP addresses for one or more GRE tunnels. For each line, type the requested configuration
information and press [Enter].
==============================================================================
Application Analytics Engine GRE Configuration
==============================================================================
Remote mirroring can be configured in Coreflow Switches using GRE tunnels.
This requires a specific mirroring configuration enabled on the switches.
Enter the SRC IP address for the GRE Tunnel [10.54.211.116]:
Enter the DST IP address for the GRE Tunnel [192.168.1.1]: 10.54.1.116
Add another GRE Tunnel (y/n) [n]? y
ExtremeAnalytics® PV-A-305 Installation Guide for version 8.1
eth4
eth5
eth4
eth5
Configuration