Communications Specifications; Communications Functions - Omron E5CC-800 Specification & Installation Instructions

Digital temperature controller (simple type), 22.5 mm wide, and din track-mounting type,
Hide thumbs Also See for E5CC-800:
Table of Contents

Advertisement

E5EC-800/E5EC-B-800/E5AC-800

Communications Specifications

Transmission line
RS-485: Multidrop
connection method
Communications
RS-485 (two-wire, half duplex)
Synchronization
Start-stop synchronization
method
Protocol
CompoWay/F, or Modbus
Baud rate *1
9600, 19200, 38400, or 57600 bps
Transmission
ASCII
code
Data bit length *1
7 or 8 bits
Stop bit length *1
1 or 2 bits
Vertical parity (none, even, odd)
Error detection
Block check character (BCC) with
CompoWay/F or CRC-16 with Modbus *2
Flow control
None
Interface
RS-485
Retry function
None
Communications
217 bytes
buffer
Communications
0 to 99 ms
response wait time
Default: 20 ms
*1 The baud rate, data bit length, stop bit length, and vertical parity can be
individually set using the Communications Setting Level.
*2 Modbus is a registered trademark of Schneider Electric.

Communications Functions

You can use the memory in the PLC to read and
write E5@C parameters, start and stop operation,
etc. The E5@C automatically performs communi-
cations with PLCs. No communications program-
ming is required.
Number of connected Temperature Controllers:
32 max. (Up to 16 for the FX Series)
Programless
Applicable PLCs
*1
communications
When Digital Temperature Controllers are con-
nected, set points and RUN/STOP commands
can be sent from the Digital Temperature Control-
Component
ler that is set as the master to the Digital Temper-
*1
Communications
ature Controllers that are set as slaves.
Slope and offsets can be set for the set point.
Number of connected Digital Temperature Con-
trollers: 32 max. (including master)
When Digital Temperature Controllers are con-
nected, the parameters can be copied from the
*2
Copying
Digital Temperature Controller that is set as the
master to the Digital Temperature Controllers that
are set as slaves.
MELSEC is a registered trademark of Mitsubishi Electric Corporation.
KEYENCE is a registered trademark of Keyence Corporation.
*1 A Temperature Controller with version 1.1 or higher is required.
A Temperature Controller with version 2.1 or higher is required for
the FX Series or the KV Series.
*2 Both the programless communications and the component
communications support the copying.
30
OMRON PLCs
CS Series, CJ Series, CP Series, NJ Series,
or NX1P
MELSEC Q Series, L Series, FX3 Series, or
iQ-R Series
KEYENCE PLCs
KEYENCE KV Series
Current Transformer (Order Separately)
Ratings
E54-CT1
E54-CT3
Dielectric strength
1,000 VAC for 1 min 1,500 VAC for 1 min
Vibration resistance
E54-CT1: Approx. 11.5 g,
Weight
E54-CT3: Approx. 50 g
E54-CT3 Only
Accessories
Armatures (2)
Plugs (2)
Heater Burnout Alarms and SSR Failure
Alarms
CT input (for heater
Models with detection for single-phase
current detection)
heaters: One input
Maximum heater
50 A AC
current
Input current indica-
±5% FS ±1 digit max.
tion accuracy
Heater burnout
0.1 to 49.9 A (in units of 0.1 A)
alarm setting range
Minimum detection ON time: 100 ms *3
*1
SSR failure alarm
0.1 to 49.9 A (in units of 0.1 A)
setting range *2
Minimum detection OFF time: 100 ms *4
*1. For heater burnout alarms, the heater current will be measured when the
control output is ON, and the output will turn ON if the heater current is
lower than the set value (i.e., heater burnout detection current value).
*2. For SSR failure alarms, the heater current will be measured when the
control output is OFF, and the output will turn ON if the heater current is
higher than the set value (i.e., SSR failure detection current value).
*3. The value is 30 ms for a control period of 0.1 s or 0.2 s.
*4. The value is 35 ms for a control period of 0.1 s or 0.2 s.
Electrical Life Expectancy Curve for
Control Output Relays (Reference
Values)
500
300
100
50
30
10
5
3
1
0
1
2
E54-CT1L
E54-CT3L
2
50 Hz, 98 m/s
E54-CT1: Approx. 14 g,
E54-CT3: Approx. 57 g
None
E5EC-800/E5EC-B-800/E5AC-800
250 VAC, 30 VDC
(resistive load)
cosφ = 1
3
4
5
6
Switching current (A)