Omron E5CC-800 Specification & Installation Instructions page 56

Digital temperature controller (simple type), 22.5 mm wide, and din track-mounting type,
Hide thumbs Also See for E5CC-800:
Table of Contents

Advertisement

E5@C-800
Operation
Parameters
The following pages describe the parameters set in each level. Pressing the M (Mode) Key at the last parameter in each level returns to the top
parameter in that level. Some parameters may not be displayed depending on the model and other settings.
: Indicates items that can be used only with the E5@C-@-0@@.
000
800
: Indicates items that can be used only with the E5@C-@-8@@.
Press the S Key
for at least 1 s.
Press the O Key less than 1 s.
Adjustment
Level
Press the O Key less than 1 s.
Adjustment Level
Display
000
Displayed only
l.adj
once when
entering
ins
adjustment level.
M
inrt
at
AT Execute/Cancel
off
M
Communications
cmwt
rss
Writing
off
M
spmd
rsrt
SP Mode
lsp
000
M
ct1
Heater Current 1
Value Monitor
0.0
M
Heater Burnout
hb1
Detection 1
0.0
M
Heater Current 2
ct2
Value Monitor
0.0
000
M
Heater Burnout
c-p
hb2
Detection 2
0.0
000
M
Leakage Current 1
c-i
lcr1
Monitor
0.0
M
c-d
hs1
HS Alarm 1
50.0
M
Leakage Current 2
lcr2
c-db
Monitor
0.0
000
M
HS Alarm 2
hs2
of-r
000
50.0
M
sp-0
SP 0
hys
0
M
sp-1
SP 1
chys
0
M
sp-2
SP 2
soak
0
M
M
sp-3
sp-3
SP 3
wt-b
0
0
M
sp-4
mv-s
SP 4
0
M
sp-5
mv-e
SP 5
0
M
sp-6
sprt
SP 6
0
M
sp-7
sprl
SP 7
0
M
ol-h
ol-l
56
Starting in Manual Mode.
*1
orl
MV Change Rate
Process Value Input
Limit
000
Shift
0.0
0.0
M
M
Position
Process Value Slope
db
1.000
Proportional
Coefficient
000
2.0
Dead Band
M
M
Remote SP Input Shift
oc-h
Open/Close
000
0.0
Hysteresis
0.8
M
M
Remote SP Input
Extraction of
sqrp
Slope Coefficient
Square Root
1.000
Low-cut Point
000
000
0
M
M
p
Proportional Band
w1on
Work Bit 1
8.0
ON Delay
000
M
M
Integral Time
i
w1of
Work Bit 1
233
OFF Delay
000
M
M
d
Derivative Time
w2on
Work Bit 2
40
ON Delay
000
M
M
Proportional Band
w2of
Work Bit 2
(Cooling)
8.0
OFF Delay
000
M
M
Integral Time
w3on
Work Bit 3
233
(Cooling)
ON Delay
000
M
M
Derivative Time
w3of
Work Bit 3
(Cooling)
40
OFF Delay
000
M
M
Dead Band
w4on
Work Bit 4
0.0
ON Delay
000
M
M
Manual Reset Value
w4of
Work Bit 4
50.0
OFF Delay
000
M
M
Hysteresis (Heating)
w5on
Work Bit 5
1.0
ON Delay
000
M
M
Hysteresis (Cooling)
w5of
Work Bit 5
1.0
OFF Delay
000
M
M
000
Soak Time
w6on
Work Bit 6
1
ON Delay
000
M
M
Wait Band
000
w6of
Work Bit 6
off
OFF Delay
000
M
MV at Stop
000
w7on
Work Bit 7
0.0
ON Delay
000
M
M
MV at PV Error
000
w7of
Work Bit 7
0.0
OFF Delay
000
M
M
SP Ramp Set Value
w8on
Work Bit 8
off
ON Delay
000
M
M
SP Ramp Fall Value
w8of
Work Bit 8
same
000
OFF Delay
000
M
M
MV Upper Limit
Communications
plcm
100.0
Monitor
0
M
M
MV Lower Limit
0.0
M
Power ON
Starting in
Manual Control Level
Automatic
Mode.
Press the O
PID
Key or the S
C
25
Control
Key for at least
0
only
1 s.
*1
PV/MV
Operation Level
25
Process Value/
al1h
Set Point 1
0
M
25
Process Value/
al1l
Set Point 2
0
M
a-m
al-2
Auto/Manual Switch
Press the
M
O Key
Multi-SP Set
m-sp
for at
al2h
Point Selection
least 3 s.
0
M
rsp
al2l
Remote SP Monitor
000
0.0
M
Set Point During
sp-m
al-3
SP Ramp
0
M
Heater Current 1 Value
ct-1
al3h
Monitor
0.0
M
Heater Current 2 Value
ct-2
al3l
Monitor
000
0.0
M
Leakage Current 1
lcr1
al-4
Monitor
0.0
M
Leakage Current 2
al4h
lcr2
Monitor
000
0.0
M
prst
000
al4l
Program Start
rset
M
Soak Time Remain
sktr
000
0
M
RUN/STOP
r-s
c-o
run
M
al-1
Alarm
v-m
Value 1
0
M
Press the O and M Keys
Press the O and M Keys for
at least 3 s.
for at least 1 s.
Protect Level
Displayed only for models with
The time taken to move to the protect level
communications. Changes are
can be adjusted by changing the "Move to
effective after cycling power or
protect level time" setting.
after a software reset.
pmov
000
Move to Protect Level
:
Displayed only when a
0
password is set. Restricts
M
moving to protect level.
Operation/Adjustment Protect
oapt
0
M
Initial Setting/Communications Protect
icpt
1
M
wtpt
Setting Change Protect
off
M
PF Key Protect
pfpt
off
M
M
chgp
Changed Parameters Only
off
M
M
Parameter Mask Enable
000
pmsk
on
M
prlp
Password to Move to
000
Protect Level
0
M
Press the S Key*2
O
Press the
Key for at least 3 s.
Other than the Auto/Manual Switch display
Initial Setting Level
Press the
Press the O Key for less than 1 s.
O Key for
at least 1 s.
in-t
Input Type
5
M
in-h
Scaling Upper Limit
100
M
Alarm Value
in-l
Scaling Lower Limit
Upper Limit
0
1
0
M
M
Decimal Point
Alarm Value
dp
Lower Limit
0
1
0
M
M
Temperature Unit
d-u
Alarm
°C, °F
Value 2
c
0
M
M
sl-h
SP Upper Limit
Alarm Value
Upper Limit
1300
0
2
M
M
sl-l
SP Lower Limit
Alarm Value
Lower Limit
-200
0
2
M
M
cntl
PID ON/OFF
Alarm
onof
Value 3
0
M
M
s-hc
Standard or
Alarm Value
Heating/Cooling
stnd
Upper Limit
0
3
M
M
st
ST (Self-tuning)
Alarm Value
on
Lower Limit
0
3
M
M
ptrn
Program Pattern
Alarm
off
Value 4
M
0
M
cp
Control Period (Heating)
20
Alarm Value
Upper Limit
M
0
4
c-cp
Control Period (Cooling)
M
20
Alarm Value
M
Lower Limit
0
4
orev
Direct/Reverse Operation
M
or-r
o
MV Monitor
M
(Heating)
0.0
alt1
Alarm 1 Type
M
2
MV Monitor
M
(Cooling)
0.0
alh1
Alarm 1
M
Hysteresis
0.2
Valve Opening
M
Monitor
0.0
alt2
Alarm 2 Type
M
2
M
Press the O Key
Alarm 2
alh2
less than 1 s.
Hysteresis
0.2
Communications
M
Setting Level
* Used with programless communications
Protocol Setting:
Highest
psel
maxu
Switches between
Communications
CompoWay/F and
cwf
0
Unit No.
Modbus.
*3
M
M
Communications
u-no
area
Area
Unit No.
1
0
M
M
Communications
bps
First Address
adrh
Baud Rate
Upper Word
9.6
0
M
M
len
First Address
Communications
adrl
Data Length
Lower Word
7
0
M
M
Communications
Receive Data
sbit
rwat
Stop Bits
Wait Time
2
1000
*3
M
M
prty
Communications
Communications
unit
Node Number
Parity
even
0
M
M
Send Data Wait
sdwt
Time
20
*1. When the PF Setting parameter is set to A-M.
M
*2. When the PF Setting parameter is set to PFDP.
*3. Used with component communications.
Press the S Key*2
000
Upload
up 1
Setting 1
1
M
Upload
up13
Setting 13
0
M
Download
dn 1
Setting 1
31
M
Download
dn13
Setting 13
75
M
copy
Copy
*3
off
SP Slope
sps
*3
1.000
M
SP Offset
spos
*3
0.0
M