Table 25 UL Compatible FX-2000 Series Addressable Loop Devices
Make Model / Base
System Sensor continued
B501BH
B501BHT
CZ-6
BEAM200
BEAM200S

13.2 FX-2000 Series Compatible Two-Wire Smoke Detectors (UL)

i
Notes:
Table 26 FX-2000 Series Compatible Two-Wire Smoke Detectors (UL Listed)
Smoke Detector Make
Compatibility
Model / Base
Identifier Head /
Base
Apollo
225 / 251, 255, 256,
55000-225 / 45681-251, -
258
255, -256, -258
325 / 251, 255, 256,
55000-325 / 45681-251, -
258
255, -256, -258
Detection Systems Inc.
B - N/A
DS250
B - N/A
DS250TH
B - N/A
DS282
B - N/A
DS282TH
Hochiki
HD-3/HB-72
DCD-135/NS6-220
HD-3/HB-3
DCD-135/NS4-220
HD-3/HB-3
DCD-135/HSC-220R
HD-3/HB-3
DCD-190/NS6-220
HD-3/HB-3
DCD-190/NS4-220
HD-3/HB-3
DCD-190/HSC-220R
86
200 Series Low Profile Intelligent Base with Horn
200 Series Low Profile Intelligent Base with Horn (Temporal Code)
Six Addressable Universal Zone Module
Intelligent Addressable Beam Detector
Intelligent Addressable Beam Detector (with Sens Test)
Whether mixing different models of compatible smoke detectors or using the
same model on the same circuit, total standby current of all detectors must not
exceed 3 mA.
The below listed smoke detectors are compatible with initiating circuits having
Compatibility Identifier "A".
Rated
Standby
Current
0.045 mA
0.045 mA
0.10 mA
0.10 mA
0.10 mA
0.10 mA
0.035mA
0.035mA
0.035mA
0.035mA
0.035mA
0.035mA
Description
Smoke Detector Make
Compatibility
Model / Base
Identifier Head /
Base
Sentrol - ESL
S10A - N/A
429C
S10A - N/A
429CT
S11A - N/A
429CST
S11A - N/A
429CRT
711U/701E, 701U, 702E,
S10A - S00
702U
712U / 701E, 701U, 702E,
S10A - S00
702U
713-5U / 701E, 701U,
S10A - S00
702E, 702U
S10A - S00
721U / 702E, 702U
732U / 702E, 702U,
S11A - S00
702RE, 702RU
S10A - S00
721UT / 702E, 702U
S10A - S00
722U / 702E, 702U
731U / 702E, 702U,
S11A - S00
702RE, 702RU
S10A - S00
721UT / 702E, 702U
S10A - S00
721UT / 702E, 702U
Appendix B: Compatible Devices
Rated Standby
Current
0.10 mA
0.10 mA
0.10 mA
0.10 mA
0.10 mA
0.10 mA
0.10 mA
0.10 mA
0.10 mA
0.10 mA
0.10 mA
0.10 mA
0.10 mA
0.10 mA