Tolerance Check For Target Weight - KERN EOC 6K-3 Operating Manual

Industrial scales
Hide thumbs Also See for EOC 6K-3:
Table of Contents

Advertisement

7.8.1 Tolerance check for target weight

Settings
Press
and
mode.
„net H" will be displayed.
Press
, the display for entering the lower limit value
„nEt Lo" appears.
Press
, the current setting will be displayed. The
decimal point at the extreme left flashes.
To enter the lower limit, e. g. 1000 Kg, press the
navigation keys (See chap. 2.2.1); the currently enabled
digit will be flashing.
Confirm input by
Press
repeatedly until „nEt H" will be displayed.
Press
, the current setting for the upper limit will be
displayed.
Press the navigation keys (see chap. 2.2.1) to enter the
upper limit, e.g. 10.000 kg; the currently enabled digit will
be flashing.
Confirm input by
Press
repeatedly until „BEEP" will be displayed.
30
at the same time in weighing
.
.
EOC-BA-e-1711

Hide quick links:

Advertisement

Table of Contents
loading