  • Page 1 KERN & Sohn GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 email: info@kern-sohn.com Internet: www.kern-sohn.com Instruction Manual Platform/floor scales KERN EOB_F Version 1.0 07/2013 EOB_F-BA-e-1310...
  • Page 2: Table Of Contents

    KERN EOB_F Version 1.0 07/2013 Operating instructions Platform/floor scales Contents Technical Data ....................3 Appliance overview ..................5 Overview of display ..................6 Keyboard overview ....................7 Basic Information (General) ................8 Proper use ......................... 8 Improper Use ......................8 Warranty ........................
  • Page 3: Technical Data

    1 Technical Data KERN 35K2F 60K2F 60K2LF Readability (d) 10 g 20 g 20 g Weighing range (max) 35 kg 60 kg 60 kg Reproducibility 10 g 20 g 20 g Linearity ± 20 g ± 40 g ± 40 g...
  • Page 4 210 x 110 x 45 (B x D x H) mm Radio transmission to Range: max. 10 m on free surface, free of buildings weighing platform Weighing surface mm 314,5 x 304,5 550 x 550 550 x 550 Weight kg (net) 13,5 13,5 EOB_F-BA-e-1310...
  • Page 5: Appliance Overview

    2 Appliance overview  Weighing plate, stainless steel  Display unit Weighing platform 314,5 x 304,5 mm Weighing platform 550 x 550 mm Power On-Off Mains connection  Display unit with wall fixing device: EOS_F-BA-e-1310...
  • Page 6: Overview Of Display

    If the display shows the stability display [ο] the balance is in a stable status. The [ο] indication disappears if the condition is unstable. Hold/animal weighing function active, see chap. 7  Weighing unit [kg lb], (see chap. 7) „Switch-over weighing unit“ Stored tare value, (see chap. 7) „Taring“ Contact-free taring field EOB_F-BA-e-1310...
  • Page 7: Keyboard Overview

    3.1 Keyboard overview Function Turn on/off balance Hold/ animal weighing function Tare balance by  The TARE button or  The contact-free taring field Switch-over weighing unit Select channel EOS_F-BA-e-1310...
  • Page 8: Basic Information (General)

    The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing. 4.3 Warranty Warranty claims shall be voided in case ...
  • Page 9: Monitoring Of Test Resources

    (www.kern-sohn.com regard to the monitoring of balance test substances and the test weights required for this. In KERN’s accredited DKD calibration laboratory test weights and balances may be calibrated (return to the national standard) fast and at moderate cost. 5 Basic Safety Precautions 5.1 Pay attention to the instructions in the Operation Manual...
  • Page 10: Unpacking, Setup And Commissioning

    The balance must be installed in a way that the weighing plate is exactly in horizontal position. Mount the display unit in a way that facilitates operation and where it is easy to see. EOB_F-BA-e-1310...
  • Page 11: Scope Of Delivery / Serial Accessories

    7.2.1 Scope of delivery / serial accessories  Platform and display unit  4 x adjustable feet (only models with weighing platform 550 x 550)  2 x Power unit  Wall fixture (with fixing screws)  Instruction Manual 7.2.2 Assembly instructions for the use of the wall fixture EOS_F-BA-e-1310...
  • Page 12: Mains Connection

    Two mains adapters are delivered. Power is supplied via the external mains adapter. The stated voltage value must be the same as the local voltage. Only use original KERN mains adapters. Using other makes requires consent by KERN. Fig. Mains connection platform 314,5 x 304,5 mm:...
  • Page 13 Fig. Battery compartment – platform 314,5 x 304,5 mm: on the top of the weighing platform (under the weighing surface) Fig. Battery compartment – platform 550 x 550 mm: on the bottom of the weighing platform EOS_F-BA-e-1310...
  • Page 14: Initial Commissioning

    To receive accurate measuring values it is also recommended to adjust the balance periodically in weighing operation. Observe stable environmental conditions. A warming up time (see chapter 1) is required for stabilization. EOB_F-BA-e-1310...
  • Page 15  In weighing mode press the UNIT key and keep it pressed until „CAL“ followed by the weight value of the required adjustment weight in displayed. „LOAd“ is displayed alternatively.   (Example)  Carefully place the required adjustment weight (see tab. 1 „Technical data“) in the centre of the weighing plate Press TARE key, adjustment is started.
  • Page 16: Start-Up

    Should the balance not display exactly zero despite empty weighing plate, press the TARE button. The balance will be set to zero after a short standby time.  Press ON/OFF button, the display disappears Switching Off  Set rocker switch next to the platform to „0“. EOB_F-BA-e-1310...
  • Page 17: Weighing

     Turn on balance by pressing the ON/OFF key Weighing  Position item to be weighed  Wait for stability display  Read weighing result.  By pressing the UNIT button the weighing result can be Switch over  weighing unit displayed in another unit [kg lb].
  • Page 18: Taring

    (adding). The limit is reached when the whole weighing range is exhausted. The weight of the weighing container will be displayed as a minus number after removing the weighing container. The tare weight is saved until it is deleted. EOB_F-BA-e-1310...
  • Page 19 Delete tare  Unload the balance and press the TARE button, or touch the taring field with your hand, the zero display appears.  The contact-free taring function can be switched on or switched off via the menu (see chap.10): „t_lr“ on „ON“ or „OFF“ EOS_F-BA-e-1310...
  • Page 20: Hold Function (Animal Weighing Function)

    The indicator [] under [HOLD] goes out, the balance returns into normal weighing mode.  Press the HOLD button once more to repeat this function as often as required. There is no average value calculation in the event of too much movement (heavy display oscillation). EOB_F-BA-e-1310...
  • Page 21: Plus/Minus Weighings

     For example for item weight check, production check etc. Plus/minus switch-on the balance using ON/OFF button and wait for weighings zero display.  Put the nominal weight on the weighing plate (Example)  Use the TARE button or the TARE-touchfield for taring to zero.
  • Page 22: Setting Channels

    Setting the channels on the platform: Switch-off platform (rocker switch on the side to „0“) Actuate the dip switch at the lower side of the platform. (pin 4 is not used). Platform 314,5 x 304, 5 mm: Platform 550 x 550 mm: EOB_F-BA-e-1310...
  • Page 23 In order to set the respective channel, put the corresponding switch to „ON“. The other pins must remain on the opposite side. * default setting channel 1 Then switch-on the platform. The new setting will be imported. The display unit changes to the zero display and thus is ready for use.
  • Page 24: Menu

     To exit the Menu and save, press the HOLD button as often as required until "END" is displayed and then confirm by pressing TARE. The balance returns automatically into weighing mode. Navigation: Factory settings are marked by *. EOB_F-BA-e-1310...
  • Page 25: Service, Maintenance, Disposal

    Spilled weighing goods must be removed immediately. 11.2 Service, maintenance The appliance may only be opened by trained service technicians who are authorized by KERN. Before opening, disconnect from power supply. 11.3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used.
  • Page 26  The balance is on an uneven surface.  Great fluctuations in temperature.  Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) Should other error messages occur, switch balance off and then on again. If the error message remains inform manufacturer. EOB_F-BA-e-1310...
  • Page 27: Declaration Of Conformity

    EN 301 489-1 v1.8.1 25.07.2013 Datum Signatur Date Signature 72336 Balingen Albert Sauter Ort der Ausstellung KERN & Sohn GmbH Place of issue Geschäftsführer Managing director KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0 Fax +49-[0]7433/9933-149, E-Mail: info@kern-sohn.com, Internet: www.kern-sohn.com EOS_F-BA-e-1310...