5.13.2 Setting user security
Enter a value between 1 and 999 in Pr 11.30 and press the
code has now been set to this value. To activate the security, the access level must be
set to Loc in Pr 11.44 (SE14, 0.35). When the drive is reset, the security code will have
been activated and the drive returns to access level L1. The value of Pr 11.30 will return
to 0 in order to hide the security code. At this point, the only parameter that can be
changed by the user is the access level Pr 11.44 (SE14, 0.35).
5.13.3 Unlocking user security
Select a read write parameter to be edited and press the
will now show CodE.
Use the arrow buttons to set the security code and press the
correct security code entered, the display will revert to the parameter selected in edit
mode. If an incorrect security code is entered the display will revert to parameter view
mode.
To lock the user security again, set Pr 11.44 (SE14, 0.35) to Loc and press the
reset button.
5.13.4 Disabling user security
Unlock the previously set security code as detailed above. Set Pr 11.30 to 0 and press
the
button. The user security has now been disabled, and will not have to be
unlocked each time the drive is powered up to allow read / write access to the
parameters.
Mentor MP Short Form Guide