Enclosure - Emerson Mentor MP Short Manual

Hide thumbs Also See for Mentor MP:
Table of Contents

Advertisement

3.6

Enclosure

Enclosure layout
Please observe the clearances in the diagram below taking into account any
appropriate notes for other devices / auxiliary equipment when planning the installation.
Figure 3-19 Enclosure layout
Ensure minimum clearances
are maintained for the drive.
Forced or convection air-flow
must not be restricted by any
object or cabling
Signal cables
Plan for all signal cables
to be routed at least
300mm (12in) from the
drive and any power cable
External
controller
Auxillary
supply
Armature
connection
cable
3.7
Fan air flow data
Refer to section 3.7 in the Mentor MP User Guide.
Mentor MP Short Form Guide
Issue Number: 5
AC supply contactor,
line chokes and fuses
Enclosure
A
≥100mm
(4in)
MA1
MA2
Field
connection cable
www.controltechniques.com
Note
For EMC compliance:
1) Power cabling must be at
≥100mm
least 100mm (4in) from the
(4in)
drive in all directions
2) Ensure direct metal contact
at drive and filter mounting
points (any paint must be
removed)
A
100mm for Size 1 drives
200mm for Size 2A/2B drives
Note
For Size 2C/2D drives
leave a clearance of 100mm
around the drive.
A