Emerson Mentor MP Short Manual page 68

Hide thumbs Also See for Mentor MP:
Table of Contents

Advertisement

23.01
RO
Txt
USEr (0), SEt UP (1), diAGnoS
(2), triPS (3), SP LOOP (4),
SintEr (5), Fb SP (6), inPut (7)
Defines the sub block headers. Can be used by the MP-Keypad to display the same
strings as the SM-Keypad.
23.02
RO
The OR of Pr 23.03 to Pr 23.09. To be used by the MP-Keypad.
Parameter
23.03
23.04
23.05
23.06
23.07
23.08
23.09
23.03 - 23.09
RW
When this parameter is set to 1 the associated pre-defined sub block is accessible.
When this parameter is 0 the associated pre-defined block is bypassed.
Parameter
23.03
23.04
23.05
23.06
23.07
23.08
23.09
68
Sub block headers
NC
Binary sum of pre-defined sub block enables
NC
0 to 127
Value
1
2
4
8
16
32
64
Pre-defined sub block enable
Bit
0 to1
Description
Set up
Diagnostic
Trips
Speed loop
Serial interface
Speed feedback
IO
www.controltechniques.com
PT
BU
USEr (0)
PT
BU
0
US
BU
1
Display
SEt UP
diAGnoS
triPS
SP LOOP
SintEr
Fb SP
InPut