Connection Manager Object - Siemens SIMATIC S7 EIP-200S System Manual

Ethernet/ip adapter distributed i/o system
Table of Contents

Advertisement

EIP-200S Ethernet/IP Adapter
2.6 Device profile: supported CIP objects
2.6.3

Connection Manager Object

The following information applies to the EIP-200S Ethernet/IP Adapter Connection Manager
Object.
Class code
Class attributes
Number of instances 1
Instance 1 attributes for Connection Manager Object
Attribute
ID
1
2
3
4
5
6
7
8
A device may reject a set request to this attribute, using General Status Code 0x09 (Invalid Attrib-
1
ute Value), if the attribute value sent is not zero.
Common services for Connection Manager Object
Service
code
0x01
0x0E
30
0x06
1, 2, 3
Need in
Access
NV
implem
rule
Optional
Set
V
1
Optional
Set
V
1
Optional
Set
V
1
Optional
Set
V
1
Optional
Set
V
1
Optional
Set
V
1
Optional
Set
V
1
Optional
Set
V
1
Implemented for
Class
Instance
Yes
Yes
Yes
Yes
Name
Data
type
Open Re-
UINT
quests
Open Format
UINT
Rejects
Open Re-
UINT
source Re-
jects
Open Other
UINT
Rejects
Close Re-
UINT
quests
Close Format
UINT
Requests
Close Other
UINT
Requests
Close Timeout UINT
Service name
Get_Attributes_All
Set_Attribute_Single
EIP-200S Ethernet/IP Adapter Distributed I/O System
System Manual, 06/2018, A5E44345053-AB
Description
Number of Forward Open service
requests received.
Number of Forward Open service
requests which were rejected due
to bad format.
Number of Forward Open service
requests which were rejected due
to lack of resources.
Number of Forward Open service
requests which were rejected for
reasons other than bad format or
lack of resources.
Number of Forward Close service
requests received.
Number of Forward Close service
requests which were rejected due
to bad format.
Number of Forward Close service
requests which were rejected for
reasons other than bad format.
Total number of connection
timeouts that have occurred in
connections controlled by this
Connection Manager.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents