Switch
Function
1
NTP/GPS
Transmitter switch settings must be set for NTP time, which is specific to the transmitter's firmware version. The
firmware version is displayed on the transmitter front LCD display in the lower-left corner. For version 1.79, set switch
1 to the UP position and switch 2 to the DOWN position. For versions below 1.79, set switch 1 and 2 to the UP
position.
2
LAN/Local
3
Aux 3 (setting unassigned)
4
Aux 4 (setting unassigned)
5
-30M
6
UTC Offset
7
Daylight Saving Time
8
12-Hour or 24-Hour Time

Verify Transmitter is Operational

The final step is to verify the system Transmitter is operating and functional.
1. Verify a GPS signal or NTP time has been received.
2. Verify the time and date displayed on the Transmitter front display are correct.
3. Verify the Channel Number is set correctly.
4. Verify the Transmitter does not have any error codes. To learn more, view "View Diagnostics Menu" on page 27.
Up Position
Receive time from NTP server.
LAN network connection is enabled.
Required for use of NTP time source.
Not applicable
Not applicable
-30 minute offset enabled
Transmitter is installed in
Newfoundland or other countries
with a -30 minute off set.
Transmitter is installed in Europe.
Daylight Saving Time is disabled.
Time is displayed in 24 hour time.
Down Position
Receive time from a GPS Receiver.
Local USB and/or serial port attached
to unit is enabled.
Not applicable
Not applicable
-30 minute off set disabled
(default position)
Transmitter is installed in North
America
Daylight Saving Time is enabled.
Time is displayed in a 12 hour time.