A2 RECORDER SPECIFICATION

I/O
types
Analog i/p
Digital i/p
Digital (logic) o/p
Relay o/p
DC output
Features
Environmental performance
Ambient temperature range
Operating:
Storage:
Humidity range
Operating:
storage:
Protection
Front panel (Standard):
Front panel (Wash down):
Behind panel:
Shock/Vibration
Altitude
Atmosphere
Electrical safety
Electromagnetic compatibility
Emissions (standard units):
Emissions (Low voltage option):
Immunity
Other approvals and compliance details
General:
PV input
Packaging
Physical
Panel mounting
Weight
Panel cutout dimension
Depth behind panel
Operator interface
Display
Controls
Power requirements
Supply voltage
Standard:
Low voltage option:
Power dissipation
Fuse type
Interrupt protection
Standard:
Low voltage option:
Battery backup
Stored data
Support time (for real-time clock)
Replacement period
Type
Ethernet communications
Type:
Protocols:
Cable type
Maximum length
Termination
USB port
Number of ports
A5e38775501-AA
September 18
Four (eight if dual input option fitted)
Two
See Table A1 for options
See Table A1 for options
See Table A1 for options
CSV archive format
EtherNet/IP (Option)
File transfer protocol (FTP)
Modbus Master (Option)
Modbus TCP slave
uhh (history file) archiving
USB port at rear of instrument
User linearization tables (four)
15 Virtual channels (each configurable as maths,
totalizer or counter).
30 Virtual channels if Modbus Master or EtherNet/IP
options fitted (no alarms on virtual channels 16 to 30)
0 to 55°C (32 to 131°F)
-20 to +70°C (-4 to 158°F)
5% to 85% RH non condensing
5% to 85% RH non condensing
IP65
IP66, NEMA12
IP10 (International)
To BS EN61131-2 (5 to 150Hz. at 1g; 1 octave per min.)
<2000 metres (6561.7ft)
Not suitable for use in explosive or corrosive atmospheres.
BS EN61010-1 (Installation category II; Pollution degree 2)
BS EN61326 Class B - Light industrial.
BS EN61326 Class A - Heavy industrial
BS EN61326 Industrial
CE and cUL, EN61010
AMS2750E compliant
RoHS
EU; China
BS EN61131-2 section 2.1.3.3.
1/4 DIN
0.44kg (15.52 oz.)
92mm x 92mm (both -0.0 +0.8) or 3.62in x 3.62in (both -0.00 +0.03 in) (Figure 2)
90mm (3.54in) (Figure 2) excluding wiring.
3.5" TFT color display (320 pixels wide x 240 pixels high)
Four navigation pushbuttons below the display screen (Page, Scroll, Lower and Raise)
100 to 230Vac ± 15% at 48 to 62Hz.
24Vac (+10% - 15%), at 48 to 62Hz, or 24Vdc (+20% -15%)
9W
None
Holdup >20ms at 85V RMS supply voltage.
Holdup >20ms at 20.4V RMS supply voltage.
Time, date.
Minimum of 1 year with unit unpowered.
Three years typical
poly-carbonmonofluoride / lithium (BR2330) (PA260195)
10/100Base-T Ethernet (IEEE802.3)
Modbus TCP/IP slave, FTP, DHCP
Category 5
100metres (110 yards)
RJ45. Green LED illuminated = link connected; Amber LED flashing shows link activity.
One at rear of instrument
FEC920: USER GUIDE
A5E45696052A Rev-AA
L = Logic output; R = Relay; D = DC output
OP4 and OP5 share Common terminals.
Table A1 Output options
Default
Options
Appendix A
Page 209