Parameter path
Channel.3.Main.ScaleLow2
Channel.3.Main.SensorBreakType
Channel.3.Main.SensorBreakVal
Channel.3.Main.Shunt
Channel.3.Main.Status
Channel.3.Main.Status2
Channel.3.Main.TestSignal
Channel.3.Main.Type
Channel.3.Main.Units
Channel.3.Trend.Colour
Channel.3.Trend.SpanHigh
Channel.3.Trend.SpanLow
Channel.4.Alarm1.Acknowledge
Channel.4.Alarm1.Acknowledgement
Channel.4.Alarm1.Active
Channel.4.Alarm1.Amount
Channel.4.Alarm1.AverageTime
Channel.4.Alarm1.Block
Channel.4.Alarm1.ChangeTime
Channel.4.Alarm1.Deviation
Channel.4.Alarm1.Dwell
Channel.4.Alarm1.Hysteresis
Channel.4.Alarm1.Inactive
Channel.4.Alarm1.Inhibit
Channel.4.Alarm1.Latch
Channel.4.Alarm1.NotAcknowledged
Channel.4.Alarm1.Reference
Channel.4.Alarm1.Status
Channel.4.Alarm1.Threshold
Channel.4.Alarm1.Type
Channel.4.Alarm2.Acknowledge
Channel.4.Alarm2.Acknowledgement
Channel.4.Alarm2.Active
Channel.4.Alarm2.Amount
Channel.4.Alarm2.AverageTime
Channel.4.Alarm2.Block
Channel.4.Alarm2.ChangeTime
Channel.4.Alarm2.Deviation
Channel.4.Alarm2.Dwell
Channel.4.Alarm2.Hysteresis
Channel.4.Alarm2.Inactive
Channel.4.Alarm2.Latch
Channel.4.Alarm2.NotAcknowledged
Channel.4.Alarm2.Reference
Channel.4.Alarm2.Status
Channel.4.Alarm2.Threshold
Channel.4.Alarm2.Type
Channel.4.Main.CJType
Channel.4.Main.CloseString
Channel.4.Main.Descriptor
Channel.4.Main.ExtCJTemp
Channel.4.Main.FaultResponse
Channel.4.Main.Filter
Channel.4.Main.InputHigh
Channel.4.Main.InputLow
Channel.4.Main.InternalCJTemp
Channel.4.Main.IPAdjustState
Channel.4.Main.IPAdjustState2
Channel.4.Main.LinType
Channel.4.Main.MeasuredValue
Channel.4.Main.MeasuredValue2
Channel.4.Main.Offset
Channel.4.Main.Offset2
Channel.4.Main.OpenString
Channel.4.Main.PV
Channel.4.Main.PV2
Channel.4.Main.RangeHigh
Channel.4.Main.RangeLow
Channel.4.Main.RangeUnits
Channel.4.Main.Resolution
Channel.4.Main.ScaleHigh
Channel.4.Main.ScaleHigh2
Channel.4.Main.ScaleLow
Channel.4.Main.ScaleLow2
Channel.4.Main.SensorBreakType
Channel.4.Main.SensorBreakVal
Channel.4.Main.Shunt
Channel.4.Main.Status
Channel.4.Main.Status2
Channel.4.Main.TestSignal
Page 126
FEC920: USER GUIDE
Description
Scale low value for the secondary input
Sensor break type (as for Channel.1.Main)
Sensor break value
Shunt value in Ohms
Channel status (as for Channel.1.Main.Status)
The secondary input PV (output) status
Channel test waveform (as for Channel.1.Main)
Channel function (as for Channel.1.Main.Type)
Units descriptor
Trend colour (as for Channel.1.Trend.Colour)
Specifies the highest PV (output value) to be displayed
Specifies the lowest PV (output value) to be displayed
1 = acknowledge alarm
1 = alarm acknowledged
1 = alarm source active, or safe but not ack'd
Rate-of-change alarm 'Amount'
Rate-of-change alarm 'Average time'
0 = Blocking alarms off; 1 = Blocking alarms on.
Rate-of-change alarm 'Change Time'
Deviation alarm 'Deviation Value'
Alarm dwell time
Alarm hysteresis value
1 = alarm source safe and ack'd (if necessary)
1 = alarm inhibited
Alarm latch type (as for Channel.1.Alarm1)
1 = alarm has not been acknowledged
Deviation alarm 'Reference' value
Alarm status (as for Channel.1.Alarm1)
Alarm trigger threshold
Alarm type (as for Channel.1.Alarm1)
1 = acknowledge alarm
1 = alarm acknowledged
1 = alarm source active, or safe but not ack'd
Rate-of-change alarm 'Amount'
Rate-of-change alarm 'Average time'
0 = Blocking alarms off; 1 = Blocking alarms on
Rate-of-change alarm 'Change Time'
Deviation alarm 'Deviation Value'
Alarm dwell time
Alarm hysteresis value
1 = alarm source safe and ack'd (if necessary)
Alarm latch type (as for Channel.1.Alarm1)
1 = alarm has not been acknowledged
Deviation alarm 'Reference' value
Alarm status (as for Channel.1.Alarm1)
Alarm trigger threshold
Alarm type (as for Channel.1.Alarm1)
Cold junction compensation type (as for Channel.1.Main)
Close String
Text string to describe the channel
External CJ temperature
Input fault response (as for Channel.1.Main)
Filter time constant
Input range maximum value
Input range minimum value
Channel internal cold junction temperature
Input Adjust state (0 = Unadjusted;1 =Adjusted)
Secondary Input Adjust state (0 = Unadjusted; 1 = Adjusted
Linearization type (as for Channel.1.Main.LinType)
Input value before linearization, scaling, adjust etc.
Measured value of the secondary input
Fixed value to be added to/subtracted from PV
Secondary input offset
Open String
The output (displayed) value of the channel.
The secondary input process variable (output) of the channel
Range high value
Range low value
Range units (as channel.1.Main.RangeUnits)
Specifies the resolution/number of decimal places
Scale high value
Scale high value for the secondary input
Scale low value
Scale low value for the secondary input
Sensor break type (as for Channel.1.Main)
Sensor break value
Shunt value in Ohms
Channel status (as for Channel.1.Main.Status)
The secondary input PV (output) status
Channel test waveform (as for Channel.1.Main.TestSignal)
A5E45696052A Rev-AA
Type
Hex
Dec
Resolution
float32
191a
6426
Set by Channel.3.Main.Resolution
uint8
190f
6415
Not applicable
uint8
1911
6417
Not applicable
float32
1905
6405
2dp
uint8
0109
265
Not applicable
uint8
0119
281
Not applicable
uint8
1902
6402
Not applicable
uint8
1900
6400
Not applicable
string_t
494b
18763 Not applicable
uint8
1920
6432
Not applicable
float32
1922
6434
Same as Channel.3.Main.PV
float32
1921
6433
Same as Channel.3.Main.PV
bool
01b6
438
Not applicable
bool
19d0
6608
Not applicable
bool
19cb
6603
Not applicable
float32
19c8
6600
Same as Channel.4.Main.PV
time_t
19ca
6602
Set by Network.Modbus.TimeFormat
uint8
19c2
6594
Not applicable
uint8
19c9
6601
Not applicable
float32
19c7
6599
Same as Channel.4.Main.PV
time_t
19c5
6597
Set by Network.Modbus.TimeFormat
float32
19c4
6596
Same as Channel.4.Main.PV
bool
19ce
6606
Not applicable
bool
19d1
6609
Not applicable
uint8
19c1
6593
Not applicable
bool
19cf
6607
Not applicable
float32
19c6
6598
Same as Channel.4.Main.PV
uint8
010e
270
Not applicable
float32
19c3
6595
Same as Channel.4.Main.PV
uint8
19c0
6592
Not applicable
bool
01b7
439
Not applicable
bool
19f0
6640
Not applicable
bool
19eb
6635
Not applicable
float32
19e8
6632
Same as Channel.4.Main.PV
time_t
19ea
6634
Set by Network.Modbus.TimeFormat
uint8
19e2
6626
Not applicable
uint8
19e9
6633
Not applicable
float32
19e7
6631
Same as Channel.4.Main.PV
time_t
19e5
6629
Set by Network.Modbus.TimeFormat
float32
19e4
6628
Same as Channel.4.Main.PV
bool
19ee
6638
Not applicable
uint8
19e1
6625
Not applicable
bool
19ef
6639
Not applicable
float32
19e6
6630
Same as Channel.4.Main.PV
uint8
010f
271
Not applicable
float32
19e3
6627
Same as Channel.4.Main.PV
uint8
19e0
6624
Not applicable
uint8
198c
6540
Not applicable
string_t
49ab
18859 Not applicable
string_t
4951
18769 Not applicable
float32
198d
6541
1dp
uint8
1990
6544
Not applicable
float32
198e
6542
1dp
float32
1984
6532
1dp
float32
1983
6531
1dp
float32
1995
6549
1dp
bool
1996
6550
Not applicable
bool
199c
6556
Not applicable
uint8
1986
6534
Not applicable
float32
1994
6548
Set by Channel.4.Main.Resolution
float32
1999
6553
Set by Channel.4.Main.Resolution
float32
1997
6551
3dp
float32
1998
6552
3dp
string_t
4987
18823 Not applicable
float32
010c
268
Set by Channel.4.Main.Resolution
float32
011c
284
Set by Channel.4.Main.Resolution
float32
1988
6536
Set by Channel.4.Main.Resolution
float32
1987
6535
Set by Channel.4.Main.Resolution
uint8
1989
6537
Not applicable
uint8
1981
6529
Not applicable
float32
198b
6539
Set by Channel.4.Main.Resolution
float32
199b
6555
Set by Channel.4.Main.Resolution
float32
198a
6538
Set by Channel.4.Main.Resolution
float32
199a
6554
Set by Channel.4.Main.Resolution
uint8
198f
6543
Not applicable
uint8
1991
6545
Not applicable
float32
1985
6533
2dp
uint8
010d
269
Not applicable
uint8
011d
285
Not applicable
uint8
1982
6530
Not applicable