Siemens FEC920 User Manual page 165

Flow energy calculator
Hide thumbs Also See for FEC920:
Table of Contents

Advertisement

Parameter path
OR.12.Input4
OR.12.Input5
OR.12.Input6
OR.12.Input7
OR.12.Input8
OR.12.Output
Program.Ch1Holdback
Program.Ch1HoldbackVal
Program.Ch1RampUnits
Program.Ch2Holdback
Program.Ch2HoldbackVal
Program.Ch2RampUnits
Program.HoldbackStyle
Program.Program
Program.RampStyle
RealTimeEvent.1.Duration
RealTimeEvent.1.OffDate
RealTimeEvent.1.OffDay
RealTimeEvent.1.OffMonth
RealTimeEvent.1.OffTime
RealTimeEvent.1.OffType
RealTimeEvent.1.OnDate
RealTimeEvent.1.OnDay
RealTimeEvent.1.OnMonth
RealTimeEvent.1.OnTime
RealTimeEvent.1.Output
RealTimeEvent.1.Type
RealTimeEvent.2.Duration
RealTimeEvent.2.OffDate
RealTimeEvent.2.OffDay
RealTimeEvent.2.OffMonth
RealTimeEvent.2.OffTime
RealTimeEvent.2.OffType
RealTimeEvent.2.OnDate
RealTimeEvent.2.OnDay
RealTimeEvent.2.OnMonth
RealTimeEvent.2.OnTime
RealTimeEvent.2.Output
RealTimeEvent.2.Type
Timer.1.ElapsedTime
Timer.1.In
Timer.1.Out
Timer.1.Time
Timer.1.Triggered
Timer.1.Type
Timer.2.ElapsedTime
Timer.2.In
Timer.2.Out
Timer.2.Time
Timer.2.Triggered
Timer.2.Type
Timer.3.ElapsedTime
Timer.3.In
Timer.3.Out
Timer.3.Time
Timer.3.Triggered
Timer.3.Type
Timer.4.ElapsedTime
Timer.4.In
Timer.4.Out
Timer.4.Time
Timer.4.Triggered
Timer.4.Type
September 18
FEC920: USER GUIDE
Description
OR Block 12, input 4. 0 = off; 1 = on
OR Block 12, input 5. 0 = off; 1 = on
OR Block 12, input 6. 0 = off; 1 = on
OR Block 12, input 7. 0 = off; 1 = on
OR Block 12, input 8. 0 = off; 1 = on
OR Block 12, output. 0 = off; 1 = on
Channel 1 holdback type
0 = Off
1 = Low
2 = High
3 = Band
Channel 1 holdback value
Channel 1 ramp units
Channel 2 holdback type (as for Program.Ch1, above)
Channel 2 holdback value
Channel 2 ramp units
Holdback style (0 = per segment; 1 = per program)
Program
Ramp style (0 = Time; 1 = Rate)
Sets the duration for the event to remain On
Sets the date in the month that the event is to switch off
Sets the day the event is to switch Off
0 = Sunday
1 = Monday
3 = Wednesday
4 = Thursday
6 = Saturday
7 = Monday to Friday
8 = Saturday to Sunday
9 = Every day
The month number when the event is to switch off
Sets the time that the event is to switch Off
0 = Duration; 1 = Time
Sets the date in the month that the event is to switch on
Sets the day on which event is to switch on (as 'OffDay', above)
The month number when the event is to switch on
Sets the time that the event is to switch On
The output from the real time event (0 = Off; 1 = On)
Selects the type of Real Time Event
0 = Off
1 = Time and Day
2 = Time and Date
Sets the duration for the event to remain On
Sets the date in the month that the event is to switch off
Sets the day the event is to switch Off (as for Event 1)
Sets the month that the event is to switch off
Sets the time that the event is to switch Off
Selects the type that will switch off the event (as for Event 1)
Sets the date in the month that the event is to switch on
Sets the day the event is to switch on (as for Event 1)
Sets the month that the event is to switch on
Sets the time that the event is to switch On
The output from the real time event (0 = Off; 1 = On)
Selects the type of Real Time Event
0 = Off
1 = Time and Day
2 = Time and Date
3 = Step
4 = Wait
5 = GoBack
Elapsed Time
Trigger/Gate input
Output (1 = On; 0 = Off)
Period for the timer (hh:mm:ss)
1 = Timer triggered; 0 = Timer not triggered
Type of Timer
0 = Disabled (off)
3 = One shot
Elapsed Time
Trigger/Gate input
Output (1 = On; 0 = Off)
Period for the timer (hh:mm:ss)
1 = Timer triggered; 0 = Timer not triggered
Type of Timer (as Timer.1.Type)
Elapsed Time
Trigger/Gate input
Output (1 = On; 0 = Off)
Period for the timer (hh:mm:ss)
1 = Timer triggered; 0 = Timer not triggered
Type of Timer (as Timer.1.Type)
Elapsed Time
Trigger/Gate input
Output (1 = On; 0 = Off)
Period for the timer (hh:mm:ss)
1 = Timer triggered; 0 = Timer not triggered
Type of Timer (as Timer.1.Type)
A5E45696052A Rev-AA
Type
Hex
bool
2db3
bool
2db4
bool
2db5
bool
2db6
bool
2db7
bool
2db8
uint8
3aa1
float32
3aa3
uint8
3aa6
uint8
3aa2
float32
3aa4
uint8
3aa7
uint8
3aa0
string_t
6abb
uint8
3aa5
time_t
30e6
uint8
30e8
uint8
30e9
2 = Tuesday
5 = Friday
uint8
30e7
time_t
30ea
uint8
30e5
uint8
30e2
uint8
30e3
uint8
30e1
time_t
30e4
bool
30eb
uint8
30e0
time_t
30f6
uint8
30f8
uint8
30f9
uint8
30f7
time_t
30fa
uint8
30f5
uint8
30f2
uint8
30f3
uint8
30f1
time_t
30f4
bool
30fb
uint8
30f0
time_t
2ee0
bool
2ee5
bool
2ee1
time_t
2ee2
bool
2ee3
uint8
2ee4
1 = On Pulse2 = On delay
4 = Min on.
time_t
2ee6
bool
2eeb
bool
2ee7
time_t
2ee8
bool
2ee9
uint8
2eea
time_t
2eec
bool
2ef1
bool
2eed
time_t
2eee
bool
2eef
uint8
2ef0
time_t
2ef2
bool
2ef7
bool
2ef3
time_t
2ef4
bool
2ef5
uint8
2ef6
Dec
Resolution
11699 Not applicable
11700 Not applicable
11701 Not applicable
11702 Not applicable
11703 Not applicable
11704 Not applicable
15009 Not applicable
15011 Same as Programmer.SetUp.Ch1PVInput
15014 Not applicable
15010 Not applicable
15012 Same as Programmer.SetUp.Ch2PVInput
15015 Not applicable
15008 Not applicable
27323 Not applicable
15013 Not applicable
12518 Set by Network.Modbus.TimeFormat
12520 Not applicable
12521 Not applicable
12519 Not applicable
12522 Set by Network.Modbus.TimeFormat
12517 Not applicable
12514 Not applicable
12515 Not applicable
12513 Not applicable
12516 Set by Network.Modbus.TimeFormat
12523 Not applicable
12512 Not applicable
12534 Set by Network.Modbus.TimeFormat
12536 Not applicable
12537 Not applicable
12535 Not applicable
12538 Set by Network.Modbus.TimeFormat
12533 Not applicable
12530 Not applicable
12531 Not applicable
12529 Not applicable
12532 Set by Network.Modbus.TimeFormat
12539 Not applicable
12528 Not applicable
12000 Set by Network.Modbus.TimeFormat
12005 Not applicable
12001 Not applicable
12002 Set by Network.Modbus.TimeFormat
12003 Not applicable
12004 Not applicable
12006 Set by Network.Modbus.TimeFormat
12011 Not applicable
12007 Not applicable
12008 Set by Network.Modbus.TimeFormat
12009 Not applicable
12010 Not applicable
12012 Set by Network.Modbus.TimeFormat
12017 Not applicable
12013 Not applicable
12014 Set by Network.Modbus.TimeFormat
12015 Not applicable
12016 Not applicable
12018 Set by Network.Modbus.TimeFormat
12023 Not applicable
12019 Not applicable
12020 Set by Network.Modbus.TimeFormat
12021 Not applicable
12022 Not applicable
Page 157

Advertisement

Table of Contents
loading

Table of Contents