6.3.2 Counting more parts

After the unit weight has been determined or entered, it is possible to use the scale for
parts counting. The scale can be tared to account for the container weight mentioned
in section 6.2.
After the scale is tared the items to be counted are added and the "Count" display will
show the number of items, computed using the total weight and the unit weight.
It is possible to increase the accuracy of the unit weight at any time during the counting
process by entering the count displayed and then pressing the [Smpl] key. You must
be certain that the quantity displayed matches the quantity on the scale before pressing
the key. The unit weight can be adjusted based upon a larger sample quantity. This
will give greater accuracy when counting larger sample sizes.

6.3.3 Automatic part weight updates

At the time of computing the unit weight (see section 6.3.1A), the scale will
automatically update the unit weight when a sample less than the sample already on
the platform is added. A beep will be heard when the value is updated. It is wise to
check the quantity is correct when the unit weight has been updated automatically.
This feature is turned off as soon as the number of items added exceeds the count
used as a sample.

6.3.4 Checkweighing

Checkweighing is a procedure to cause an alarm to sound when the number of items
counted on the scale meets or exceeds a number stored in the memory by using the
[check] key.
Pressing the [Check] key will bring up "Lo" in the weight display, enter a numeric
value using the numbers on the keypad and pressing the [Tare]  enter button to
confirm.