Redo an ODS/Modal measurement
You can store one set of data per measurement point/direction. However, you can
overwrite a measurement.
Procedure
1.
2.
9.7.6
Copy ODS/Modal data
Copy data stored on one measurement point/direction to another measurement point/
direction. Use this option if you could not mount a sensor at a location, and you assume
the vibration is the same for other points.
Procedure
1.
2.
3.
4.
9.8
Display the data for a ODS/Modal
measurement point
1.
2.
3.
4.
5.
294
Activate a job.
From the ODS/Modal main menu, use the up and down arrow keys or the F9 Point
Search key to select a measurement point.
Press F5 Clear Data.
Press Enter.
The analyzer clears the data from only the active point.
From the ODS/Modal main menu, press F9 Point Search or use the arrows on the
keypad to go to a measurement point.
Press Enter to collect data.
Select the measurement point to copy.
From the ODS/Modal main menu, press ALT > F9 Copy Data.
Press F10 Paste From to paste the data to another measurement point.
Press Enter.
Activate a job.
From the ODS/Modal main menu, use the up and down arrow keys or press F9 Point
Search to go to the desired measurement point.
Press F7 Display Data.
If the measurement point does not have any stored data, this option is unavailable.
Review or modify the plots as necessary.
Press Enter.