2. Install the bezel lock or a Kensington security lock.
For more information, see the lock documentation.
The installation is complete.
Drive options
Drive support information
The Cavium ThunderX2 processor provides SATA 6Gb/s support. The chassis supports two low-profile LFF
SATA hot-plug drives per server node.
Drive installation guidelines
Observe the following general guidelines:
•
The system automatically sets all drive numbers.
•
If only one drive is used, install the drive in the node 1, drive bay 1.
For drive numbering, see Drive bay numbering on page 12.
•
Drives with the same capacity provide the greatest storage space efficiency when grouped into the same
drive array.
Installing an LFF hot-plug drive
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays
are populated with either a component or a blank.
Procedure
1. If installed, remove the front bezel.
2. Remove the drive blank.
38
Hardware options installation