Cisco ASR 9000 Series Configuration Manual page 15

Aggregation services router
Hide thumbs Also See for ASR 9000 Series:
Table of Contents

Advertisement

ROM Monitor Overview
Command or Action
Step 4
config-register boot-mode rom-monitor location <node-id> command,
exit command and reload command or
config-register boot-mode rom-monitor location all command and
reload location all command.
Example:
RP/0/RSP0/CPU0:router(admin)#
config-register boot-mode rom-monitor location 0/RSP0/CPU0
RP/0/RSP0/CPU0:router(admin)# exit
RP/0/RSP0/CPU0:router# reload
Or,
RP/0/RSP0/CPU0:router(admin)# config-register boot-mode
rom-monitor
location all
RP/0/RSP0/CPU0:router(admin)# reload location all
OL-30420-01
Resetting the Configuration Register and Reloading a RSP Card to ROM Monitor Mode
Cisco ASR 9000 Series Aggregation Services Router ROM Monitor Configuration Guide, Release 5.1.x
Purpose
• Enter the following commands to place only one
RSP card (active or standby) in ROM Monitor
mode:
• Enter the boot-mode rom-monitor location
<node-id> command, where <node-id> is the ID
of the card, to set the configuration register for
ROM Monitor mode during the next card reload.
• Enter the exit command to exit administration
EXEC mode.
• Enter the reload command to reload the card and
enter ROM Monitor mode.
Note
• If you specify the config-register
boot-mode rom-monitor
command without the location
keyword, then all the RSPs are
placed in ROM Monitor mode.
• Enter the following commands to place all RSPs
in ROM Monitor mode:
• Enter the config-register boot-mode rom-monitor
location all command to reset the configuration
register for all RSPs in the system.
• Enter the reload location all command in
administration EXEC mode to reload all RSPs in
the system.
Make sure you have access to the console ports
Note
of both RSP0 and RSP1 cards on the system.
To enter the system to the ROM Monitor
mode, press Ctrl-C a few times on both RSP0
and RSP1 consoles until you get to the ROM
Monitor mode.
Caution
Resetting the configuration register may
change the baud rate for the console. The
default baud rate is 9600.
Tip
To verify the configuration register setting, enter
the show variables boot command in the
administration EXEC mode.
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents