Assignment Table For Brake Resistors; Fuses And Cable Cross−Sections - Lenze 9350 Operating Instructions Manual

Braking unit
Table of Contents

Advertisement

3
Technical data
Rated data

Assignment table for brake resistors

3.3.2
Assignment table for brake resistors
The assignment is carried out on the basis of the motor power and applies up to
the limit value specified.
Motor
power
[kW]
< 2.6
< 5.2
< 7.4
< 11
< 13.2
< 20.3
< 30
1)
The resistors are designed for a cycle of:
max. 15 s of braking with peak braking power
ƒ
at least 150 s recovery time after braking
ƒ
3.3.3
Fuses and cable cross−sections
Type
9351
9352
1)
22
1)
Type
[W]
ERBD180R300W
180
ERBD082R600W
82
ERBD068R800W
68
ERBD047R01K2
47
ERBD033R02K0
33
ERBD022R03K0
22
ERBD018R03K0
18
Recommended Lenze brake resistor for U
Fuses
VDE
20 A
50 A
Use terminal pinsif a flexible cable is used
R
Peak braking
power
[kW]
3.0
6.0
8.0
12
17
26
32.5
= 765 V or U
z
UL
mm
20 A K5
40 A K5
l
Rated power
Thermal capacity
[kW]
[kWs]
0.3
45
0.6
90
0.8
120
1.2
180
2.0
300
3.0
450
3.0
450
= 725 V
z
Cable cross−section
2
AWG
2.5
12
1)
6
10
EDBMB935X EN 8.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emb9351-eEmb9352-eEmb9351-cEmb9352-c

Table of Contents