Advantech Adam 4000 Series User Manual page 127

Data acquisition modules
Hide thumbs Also See for Adam 4000 Series:
Table of Contents

Advertisement

Table 4.26: ADAM-4080 Command Table
$AA4
Read Filter Status
Set Minimum Input
$AA0H(data)
Signal Width at High
Level
Read Minimum Input
$AA0H
Signal Width at High
Level
Set Minimum Input
$AA0L(data)
Signal Width at Low
Level
Read Minimum Input
$AA0L
Signal Width at Low
Level
Set Non-isolated
$AA1H(data)
High Trigger Level
Read Non-isolated
$AA1H
High Trigger Level
Set Non-isolated Low
$AA1L(data)
Trigger Level
Read Non-isolated
$AA1L
Low Trigger Level
Set Initial Count
@AAPN(data)
Value of Counter N
Read Initial Count
@AAGN
Value of Counter N
Enable Alarm of
@AAEAN
Counter N
Disable Alarm of
@AADAN
Counter N
Set Alarm Limit Value
@AAPA(data)
of Counter 0
Set Alarm Limit Value
@AASA(data)
of Counter 1
Read Alarm Limit
@AARP
Value of Counter 0
Read Alarm Limit
@AARA
Value of Counter 1
Set Digital Output
@AADO (data)
Values
Read Digital Output
@AADI
and Alarm Status
The addressed counter frequency
module returns the status of its digital
filter
Sets the minimum input signal width
at high level for a specified counter/
frequency module
Reads the minimum input signal
width setting at high level for a speci-
fied counter/frequency module
Sets the minimum input signal width
at low level for a specified counter/
frequency module
Reads minimum input signal width
setting at low level for a specified
counter/frequency module
Sets the high trigger level of non-iso-
lated input signals for a specified
counter/frequency module
Requests the addressed counter
frequency module to return the high
trigger level for non-
isolated input signals
Sets the low trigger level of non-iso-
lated input signals for a specified
counter/frequency module
Sets the initial count value of the
module for counter 0 or counter 1
Reads the initial count value of
counter 0 or counter 1
Enable alarm for the specified
counter 0 or counter 1
Disable alarm for the specified
counter 0 or counter 1
Download the alarm limit value for
counter 0 of the specified module
Download the alarm limit value for
counter 1 of the specified module
Ask the module to return the alarm
limit value of counter 0
Ask the module to return the alarm
limit value of counter 1
Set the values of the module's two
digital outputs (ON or OFF)
Ask the module to return the
status state of its two digital outputs
and the status of its alarm.
113
ADAM-4000 Series User Manual
7-50
7-51
7-52
7-53
7-54
7-55
7-56
7-57
7-58
7-61
7-62
7-63
7-64
7-65
7-65
7-66
7-66
7-67
7-68