1. General Information

These instructions should be read carefully and retained for further reference
and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the
PIR sensor is switched off and the circuit supply fuses are removed
or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used for
the installation of this PIR sensor and install in accordance with the
current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this PIR
sensor is fitted does not exceed the rating of the circuit cable,
fuse or circuit breaker.

3. Technical Specifications

1
• 230V AC 50 Hz
• This PIR is of Class l construction and should be earthed
• Motion Detection Range:
• Detection Angle:
• Maximum Switching Load:
• Not suitable for use with Discharge Lighting
• Time ON Adjustment:
• Dusk Level Adjustment:
• Operating Temperature:
• IP55 Rated suitable for restricted external applications
• CE Compliant
Up to 12m at 2.5m mounting height
180°
2300W Halogen Lighting
500W Fluorescent Lighting
250W LED Lighting (PF>=0.9)
5 seconds to 15 minutes
Day & Night or Night time only operation
-20°C to +40°C