  • Page 1 180° PIR Light Controller Model: STLB1000 – Black Model: STLW1000 – White...
  • Page 2: General Information

    1. General Information These instructions should be read carefully and retained for further reference and maintenance. 2. Safety • Before installation or maintenance, ensure the mains supply to the PIR light controller is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
  • Page 3: Technical Specifications

    3. Technical Specifications • 230V AC 50 Hz • This PIR light controller is of class II construction and must not be earthed • Motion Detection Range: Up to 8 to 12 metres at a 2.5m mounting height • Detection Angle: 180°...
  • Page 4: Selecting A Location

    4. Selecting a Location • The motion detector has number of detection zones, at various vertical and horizontal angles as shown (See image “A”). • The best all-round coverage is achieved with the unit mounted at the optimum height of 2.5 metres. •...
  • Page 5: Installation

    5. Installation • Ensure the mains supply is switched off and the circuit supply fuses are removed or the circuit breaker turned off. • An isolating switch should be installed to enable the power to be switched ON and OFF for maintenance purposes and to activate the manual/auto override function.
  • Page 6 • Terminate the cables into the terminal block ensuring correct polarity is observed and that all bare conductors are sleeved (See section 6. Connection Diagram). • Line the PIR light controller up with the back plate, apply pressure to both sides of the unit until both catches click into place to ensure a weatherproof seal.
  • Page 7: Connection Diagram

    6. Connection Diagram • Connect the 230V 50Hz mains supply and load cables into the terminal block as follows; 230V 50Hz Mains Supply Load (Light Source) Live Supply (Brown or Red) to L Switch Live (Brown or Red) to L’ Neutral Supply (Blue or Black) to N Neutral Load (Blue or Black) to N...
  • Page 8 7. Walk Test Procedure (Test Mode) • The sensor will rotate from left to right, and can tilt downwards. Adjust the sensor to point in the required direction and angle down to limit forward range as required. • The adjustment knobs located beneath the PIR light controller are factory set to “Walk Test Mode”...
  • Page 9 • Walk across the detection area. Each time you are detected the lamp will illuminate. • Now stand still until the lamp extinguishes (this should take approx. 3 seconds). Start moving again after 2 seconds, and the lamp will illuminate. •...
  • Page 10: Manual Override Mode

    9. Manual Override Mode The light can be switched ON for longer time periods by use of the Manual Override Mode. This can be activated at night by using the isolation switch. • Switch the isolation switch once (OFF/ON) within 1.5 seconds. •...
  • Page 11: Year Guarantee

    Note: A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK. All shipping costs are to be paid in advance before a replacement...
  • Page 12 If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline; HELPLINE 020 8450 0515 or email helpline @ timeguard.com Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query.