8. Setting Up
Walk Test Procedure
• The sensor will rotate from left to right, and tilt up or down. Adjust the
sensor to point in the required direction and angle down to limit forward
range as required.
• Set the two adjustment controls on the underside of the unit
(see diagram C) to the following positions:
TIME – Fully anti-clockwise
DUSK – Fully clockwise.
• Turn the power to the unit on. The lamp will illuminate for approximately
35 seconds. This indicates the unit is wired correctly. The unit is in
Automatic Mode when the light turns off.
• If the detection area is too small for your requirements, try angling the
sensor head up. This will increase the detection area. Angling the head
downwards will reduce the detection area should a smaller coverage
6
be required.
Setting Up for Automatic Operation
• When walk tests are complete, the unit can be adjusted for automatic
operation:
The TIME setting controls how long the unit remains illuminated following
activation & after all motion ceases. (See diagram C, the time adjustment
knob is indicated by the 'Clock' symbol).
• The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the
maximum time (fully clockwise) is approximately 15 minutes.
• Set the control to the desired setting between these limits.
• The DUSK control determines the level of darkness required for the unit to
start operating (see diagram C). The DUSK adjustment knob is indicated
by the 'Moon' and 'Sun' symbols).
• Set the light threshold to maximum (fully clockwise/Sun end), then turn
the control anti-clockwise about three quarters of the way round to the
Moon end. This will give operation after DUSK approximately.