1. General Information
These instructions should be read carefully and retained for further
reference and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to
the PIR sensor is switched off and the circuit supply fuses
are removed or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or employed
for the installation of this PIR sensor and that it is installed in accordance
with current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this
PIR sensor is fitted does not exceed the rating of the circuit cable,
fuse or circuit breaker.
• Secure device with 10A rated air breaker.
3. Technical Specifications
1
• 230V AC 50Hz
• This PIR sensor is of class II construction and must not be earthed
• Motion Detection Range:
• Presence Detection Range:
• Detection Angle:
• Maximum Switching Load:
• Time ON Adjustment:
• Dusk Level Adjustment:
• Manual Override:
• Ceiling Cut-out:
• IP44 Rated, suitable for restricted internal applications
Up to 8 meters diameter
at a 3m mounting height
Up to an 4 metres diameter
at a 3m mounting height
360°
2000W Halogen Lighting,
500W Fluorescent (low-loss ballast)
Lighting, 200W Fluorescent (electronic
ballast) Lighting, 250W LED (PF>=0.9)
Lighting, 75W Fan
3 seconds to 18 minutes.
Day & Night or Night-time only operation
(1 to 1000 Lux).
Pulse, for approximately 6 hours
ON time max.
Requires a 75mm diameter ceiling cut-out
Need help?
Do you have a question about the SLFM360N and is the answer not in the manual?