Modbus Register Map (Cont' D ) - Siemens Milltronics SF 500 Instruction Manual

Table of Contents

Advertisement

Type
Description
PID 1 Proportional Term
PID 2 Proportional Term
PID 1 Integral Term
PID 2 Integral Term
PID 1 Derivative Term
PID 2 Derivative Term
PID Tuning
PID 1 Feed Forward Term
PID 2 Feed Forward Term
PID 1 Remote Setpoint
Ratio
PID 2 Remote Setpoint
Ratio

Modbus Register Map (cont' d )

Format (R40,062)
This value determines the format of all unsigned, double-register integers (UINT32),
except for those in the direct parameter access.
0 indicates that the most significant byte (MSB) is given first
1 indicates that the least significant byte (LSB) is given first
For more information on this data format see page 87
Device Identifier (R40,064)
This value identifies the Siemens Milltronics device type and is "2" for the SF 500.
Handshaking Area (Parameter Access)
An advanced handshaking area is built into the SF 500. Use it to read and write 32 bit
parameters.
Mapping
Parameter Read and Write (40,090 – 40,095) is a series of six registers that are used for
reading and writing parameter values to and from the SF 500. The first three registers are
always unsigned integers representing parameters and index values. The second three
registers are the format and value(s) of the parameter.
Page 80
Start
41,400
41,402
41,404
41,406
41,408
41,410
41,412
41,414
41,416
41,418
Milltronics SF 500 - INSTRUCTION MANUAL
Parameter
# R
Read Reference
Values
2
32 bits
2
32 bits
2
32 bits
2
32 bits
2
32 bits
2
32 bits
2
32 bits
2
32 bits
2
32 bits
2
32 bits
r/w
see P405
page 107
r/w
r/w
see P406
page 108
r/w
r/w
see P407
r/w
page 108
r/w
see P408
page 108
r/w
r/w
see P418
page 109
r/w
7ML19985CN01