Vme-Mxi-2 Configuration And Installation; Configure The Vme-Mxi-2 - National Instruments MXI-2 Reference Manual

Hide thumbs Also See for MXI-2:
Table of Contents

Advertisement

VME-MXI-2 Configuration
and Installation
Caution
Electrostatic discharge can damage several components on your VME-MXI-2
module. To avoid such damage in handling the module, touch the antistatic plastic package
to a metal part of your VMEbus chassis before removing the VME-MXI-2 from the
package.

Configure the VME-MXI-2

© National Instruments Corporation
This chapter contains the instructions to configure and install the
VME-MXI-2 module. This chapter applies only if your kit contains a
VME-MXI-2. If you ordered the VXI kit, you should refer to Chapter 5,
VXI-MXI-2 Configuration and
Configuration and
Installation.
Configuring the VME-MXI-2 is optional. A typical configuration can use
the default settings.
This section describes how to configure the following options on the
VME-MXI-2:
VMEbus A16 base address
MXIbus termination
Configuration EEPROM
Onboard DRAM
VME-MXI-2 intermodule signaling
The VME-MXI-2 automatically detects if it is located in the first slot of the
chassis to perform the VMEbus System Controller functions. It is not
necessary to configure the VMEbus System Controller option. You can
install the module in any slot of a VMEbus chassis.
Installation, or Chapter 6,
7-1
MXI-2 Configuration Reference Manual
7
VXI-MXI-2/B