Do not install a device configured for Slot 0 into another slot without first
Caution
reconfiguring it to either Non-Slot 0 or automatic configuration. Neglecting to do this
could result in damage to the device, the VXIbus backplane, or both.
© National Instruments Corporation
a. Automatic Slot 0 Detection (Default)
Figure 6-3. VXIbus Slot Configuration
When the VXI-MXI-2/B is installed in Slot 0, it becomes the VMEbus
System Controller. In this role, it has VMEbus Data Transfer Bus Arbiter
circuitry that accepts bus requests on all four VMEbus request levels,
prioritizes the requests, and grants the bus to the highest priority requester.
As VMEbus System Controller, the VXI-MXI-2/B also drives the 16 MHz
VMEbus system clock using an onboard 16 MHz oscillator.
As required by the VXIbus specification, the VXI-MXI-2/B drives the
10 MHz signal CLK10 on a differential ECL output when installed in
Slot 0. When not installed in Slot 0, the VXI-MXI-2/B receives only the
CLK10 signal.
Chapter 6
VXI-MXI-2/B Configuration and Installation
Non
Slot 0
Auto
Slot 0
W3
Non
Slot 0
Auto
Slot 0
W3
b. Manual Slot 0 Configuration
Non
Slot 0
Auto
Slot 0
W3
c. Manual Non-Slot 0 Configuration
6-5
MXI-2 Configuration Reference Manual