Macro

The data, of which a value is not determined at the job setting such as a date and time when the trigger condition is satisfied,
is set with a macro name and replaced to data in an MES interface module.
The following shows the specification of macro according to the classification.
Macro list
■Time at trigger monitoring
Data type
Date and time
■Time at trigger ON
Data type
Date and time
■Job execution start date and time
Data type
Date and time
■Server date and time
Data type
Date and time
■Failure Action No.
Data type
Word [Unsigned]/Bit String [16-bit]
■Date and time character string
Data type
Character string [Unicode]
Up to 64 characters
2 SPECIFICATIONS
40
2.4 Usable Data for MES Interface Module
Description
A date and time when the monitoring of a trigger condition starts.
Description
A date and time when the trigger condition of a job is satisfied.
Description
A date and time when the first action of a job starts.
Description
A server date and time at DB field insertion/update.
• Outputs the value as an identifier of the macro to DB Connection Service.
• MES interface module does not have a data type since the value is not used.
• When checking the setting of the data assignment function with MES Interface Function Configuration
Tool, it is handled as a date and time.
Description
An action number executed when a processing failed.
■Upper 8 bits (processing type)
• 1: Pre-processing
• 2: Main processing
• 3: Post-processing
■Lower 8 bits (action number)
• 1 to 20: Action number
Description
A character string converted the time, when the trigger condition is satisfied, based on the specified
format.
Specifies a format character string when using macro.
The following characters in the format character strings are replaced by numeric values.
Example) 'YYYY-MM-DD hh:mm:ss.fff OFFSET' → '2015-02-01 13:05:43.532 +09:00'.
■Characters to
■Values to be replaced (When a value has a small number of the digits, '0' is
be replaced
added to the head.)
• YYYY
• Year (4 digits)
• YY
• Year (last 2 digits)
• MM
• Month (01 to 12)
• DD
• Day (01 to 31)
• hh
• Hour (00 to 23)
• mm
• Minute (00 to 59)
• ss
• Second (00 to 59)
• fff
• Decimal part of second: Millisecond (000 to 999)