Quick Links

LZR
®
-S600
LASER SCANNER FOR BUILDING AUTOMATION & SECURITY
with max. detection range of 82 ft x 82 ft
User's Guide
Visit website for
available languages of
this document.
75.5792.08 LZR-S600 20220429
Page 1 of 12

Advertisement

Table of Contents
loading

Summary of Contents for BEA LZR-S600

  • Page 1 ® -S600 LASER SCANNER FOR BUILDING AUTOMATION & SECURITY with max. detection range of 82 ft x 82 ft User’s Guide Visit website for available languages of this document. 75.5792.08 LZR-S600 20220429 Page 1 of 12...
  • Page 2: Installation And Maintenance

    If permanently powered in temperature changes. laser windows. needed, wipe only with environments where the a soft, clean and damp temperature can drop microfibre cloth. below 35 °F. Page 2 of 12 75.5792.08 LZR-S600 20220429...
  • Page 3: Led Signal

    All 4 LEDs can be switched off and on again by remote control. This can be useful in cases where the sensor should not draw any attention. SYMBOLS Possible Remote control Caution! remote control sequence Laser radiation adjustments Factory values Alarm Quick installation 75.5792.08 LZR-S600 20220429 Page 3 of 12...
  • Page 4: How To Use The Remote Control

    30 minutes after last use, the sensor locks access to the remote control session. To regain access, cycle the power. The remote control session will then be accessible for another 30 minutes. 30’ Page 4 of 12 75.5792.08 LZR-S600 20220429...
  • Page 5: Possible Applications

    During night time, field 2 is active as well triggers relay 1. and triggers relay 2 (intrusion alarm). Adapt the field width of field 1 (ex: 20 ft): Adapt the field width of field 2 (ex: 25 ft): 75.5792.08 LZR-S600 20220429 Page 5 of 12...
  • Page 6 Learn is to be (no polarity) performed (minimum of 1 millisecond). No Learn via input: connect orange and orange/black wires to ground/ common Page 6 of 12 75.5792.08 LZR-S600 20220429...
  • Page 7 WITHOUT BACKGROUND The sensor memorizes the floor as reference No reference point is memorized. point and signals a fault when its orientation No alarm in case of interference. is changed (observe orange flashing LED). 75.5792.08 LZR-S600 20220429 Page 7 of 12...
  • Page 8 Stay outside of the detection field to avoid disturbances. To launch a Learn via remote control, use the following sequence: max. 30 s Wait for the sensor to learn its environment or lock it by green remote control. Page 8 of 12 75.5792.08 LZR-S600 20220429...
  • Page 9 P – NC A – NO P = passive R1 R2 NO = normally open P – NC A – NO P – NC A – NO NC = normally closed R = relay output 75.5792.08 LZR-S600 20220429 Page 9 of 12...
  • Page 10: Troubleshooting

    Cut and restore power supply. No code is required to unlock during the unlock an incorrect code was used first minute after powering. Can’t find your answer? Visit www.beainc.com or scan QR code for Frequently Asked Questions! Page 10 of 12 75.5792.08 LZR-S600 20220429...
  • Page 11: Technical Specifications

    30%, homogenous 2006/95/EC: LVD 2004/108/EC: EMC IEC 60825-1:2007 IEC 61000-6-2:2005 Norm conformity: 2002/95/EC: RoHS IEC 60529:2001 IEC 60950-1:2005 IEC 61000-6-3:2006 Specifications are subject to change without prior notice. All values measured in specific conditions. 75.5792.08 LZR-S600 20220429 Page 11 of 12...
  • Page 12 BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose. BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/ gates, and factory-trained for the type of door/gate system.