Danfoss VLT AQUA FC 202 Operating Instructions Manual page 87

Hide thumbs Also See for VLT AQUA FC 202:
Table of Contents

Advertisement

How to programme the freque...
0-20 Display Line 1.1 Small
Option:
Function:
[953]
Profibus Warning
Displays Profibus communication
Word
warnings.
[1005] Readout Transmit
View the number of CAN control
Error Counter
transmission errors since the last
power-up.
[1006] Readout Receive
View the number of CAN control
Error Counter
receipt errors since the last power-up.
[1007] Readout Bus Off
View the number of Bus Off events
Counter
since the last power-up.
[1013] Warning
View a DeviceNet-specific warning
Parameter
word. One separate bit is assigned to
every warning.
[1230] Warning
Parameter
[1500] Operating hours
View the number of running hours of
the frequency converter.
[1501] Running Hours
View the number of running hours of
the motor.
[1502] kWh Counter
View the mains power consumption
in kWh.
[1580] Fan Running
Hours
[1600] Control Word
View the Control Word sent from the
frequency converter via the serial
communication port in hex code.
[1601] Reference [Unit]
Total reference (sum of digital/analog/
preset/bus/freeze ref./catch up and
slow-down) in selected unit.
[1602] Reference [%]
Total reference (sum of digital/analog/
preset/bus/freeze ref./catch up and
slow-down) in percent.
[1603] Status Word
Present status word
[1605] Main Actual Value
One or more warnings in a Hex code
[%]
[1609] Custom Readout
View the user-defined readouts as
defined in 0-30 Custom Readout Unit,
0-31 Custom Readout Min Value and
0-32 Custom Readout Max Value.
[1610] Power [kW]
Actual power consumed by the motor
in kW.
[1611] Power [hp]
Actual power consumed by the motor
in hp.
[1612] Motor Voltage
Voltage supplied to the motor.
[1613] Frequency
Motor frequency, i.e. the output
frequency from the frequency
converter in Hz.
[1614] Motor current
Phase current of the motor measured
as effective value.
VLT AQUA Drive FC 202 Operation Instructions
0-20 Display Line 1.1 Small
Option:
[1615] Frequency [%]
[1616] Torque [Nm]
[1617] Speed [RPM]
[1618] Motor Thermal
[1622] Torque [%]
[1630] DC Link Voltage
[1632] Brake Energy /s
[1633] Brake Energy /2
[1634] Heatsink Temp.
[1635] Inverter Thermal
[1636] Inv. Nom. Current
[1637] Inv. Max. Current
[1638] SL Controller
[1639] Control Card
[1650] External
[1652] Feedback[Unit]
[1653] Digi Pot
MG20P402 - Rev. 2013-12-16
Function:
Motor frequency, i.e. the output
frequency from the frequency
converter in percent.
Present motor load as a percentage
of the rated motor torque.
Speed in RPM (revolutions per
minute) i.e. the motor shaft speed in
closed loop based on the entered
motor nameplate data, the output
frequency and the load on the
frequency converter.
Thermal load on the motor, calculated
by the ETR function. See also
parameter group 1-9* Motor
Temperature.
Shows the actual torque produced, in
percentage.
Intermediate circuit voltage in the
frequency converter.
Present brake power transferred to an
external brake resistor.
Stated as an instantaneous value.
Brake power transferred to an
min
external brake resistor. The mean
power is calculated continuously for
the most recent 120 seconds.
Present heat sink temperature of the
frequency converter. The cut-out limit
is 95 ±5 °C; cutting back in occurs at
70 ±5 °C.
Percentage load of the inverters
Nominal current of the frequency
converter
Maximum current of the frequency
converter
State of the event executed by the
State
control
Temperature of the control card.
Temp.
Sum of the external reference as a
Reference
percentage, i.e. the sum of analog/
pulse/bus.
Signal value in units from the
programmed digital input(s).
View the contribution of the digital
Reference
potentiometer to the actual reference
Feedback.
5
5
85