Thermal Configuration > Platform Thermal Configuration
Function
Automatic Thermal Reporting
Active Trip Point Lo Fan
Passive TC1 Value
Passive TC2 Value
Passive TSP Value
Thermal Sensor Device
Enable
ME SMBus Thermal Reporting
www.kontron.com
Selection
Description
Disabled
Configure _CRT, _PSV, and _AC0 automatically based on
Enabled
values recommended in BWG's Themal Reporting for Thermal
Management settings. Set to Disabled for manual
configuration.
Disabled
This value controls the temperature of the ACPI Active Trip
15, 23, ...55, ...119
Point – the point where the OS turns the processor fan on low.
1, 2, ...16
This value sets the TC1 value for the ACPI Passive Cooling
Formula.
Use "+" and "-" keys to change value.
1, 2, ..., 5, ...16
This value sets the TC2 value for the ACPI Passive Cooling
Formula.
Use "+" and "-" keys to change value.
2, 4, ..., 10, ...32
This value sets the TSP value for the ACPI Passive Cooling
Formula. It represents in tenths of a second how often the OS
reads the temperature when passive cooling is enabled. Use
"+" and "-" keys to change value.
Disabled
Enable Thermal Sensor Device.
Enabled
Disabled
Enable/Disable ME SMBus Thermal Reporting Configuration.
Enabled
mITX-BDW-U – User Guide, Rev. 1.6