Kontron mITX-BDW-U Manual
Hide thumbs Also See for mITX-BDW-U:

Advertisement

Quick Links

Our company network supports you worldwide with offices in Germany, Austria,
Switzerland, Great Britain and the USA. For more information please contact:
FORTEC Elektronik AG
Hauptniederlassung
Lechwiesenstr. 9
86899 Landsberg am Lech
Telefon:
+49 (0) 8191 91172-0
Telefax:
+49 (0) 8191 21770
E-Mail:
sales@fortecag.de
Internet:
www.fortecag.de
FORTEC Elektronik AG
Büro Wien
Nuschinggasse 12
A-1230 Wien
Telefon:
+43 1 8673492-0
Telefax:
+43 1 8673492-26
E-Mail:
office@fortec.at
Internet:
www.fortec.at
The information contained in this document has been carefully researched and is, to the best
of our knowledge, accurate. However, we assume no liability for any product failures or
damages, immediate or consequential, resulting from the use of the information provided
herein. Our products are not intended for use in systems in which failures of product could
result in personal injury. All trademarks mentioned herein are property of their respective
owners. All specifications are subject to change without notice.
Manual
mITX-BDW-U
Kontron
FORTEC Elektronik AG
Büro West
Hohenstaufenring 55
50674 Köln
Telefon:
+49 (0) 221 272 273-0
Telefax:
+49 (0) 221 272 273-10
E-Mail:
west@fortecag.de
Internet:
www.fortecag.de
ALTRAC AG
(Tochter der FORTEC):
Bahnhofstraße 3
CH-5436 Würenlos
Telefon:
+41 (0) 44 7446111
Telefax:
+41 (0) 44 7446161
E-Mail:
info@altrac.ch
Internet:
www.altrac.ch

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the mITX-BDW-U and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kontron mITX-BDW-U

  • Page 1 Manual mITX-BDW-U Kontron Our company network supports you worldwide with offices in Germany, Austria, Switzerland, Great Britain and the USA. For more information please contact: FORTEC Elektronik AG FORTEC Elektronik AG Hauptniederlassung Büro West Lechwiesenstr. 9 Hohenstaufenring 55 86899 Landsberg am Lech 50674 Köln...
  • Page 2  USER GUIDE mITX-BDW-U KTD-NOXXX-A...
  • Page 3: Table Of Contents

    02.04. DISCLAIMER ..................................4 02.05. LIFE SUPPORT POLICY ..............................4 02.06. WARRANTY ..................................5 02.07. KONTRON AG TECHNICAL SUPPORT AND SERVICES ..................5 INTRODUCTION .................................... 7 INSTALLATION PROCEDURE ..............................8 04.01. INSTALLING THE BOARD ............................. 8 04.02........................................ 9 SYSTEM SPECIFICATIONS ................................ 11 05.01.
  • Page 4 SLOT CONNECTORS (MINIPCIE) ............................44 ON-BOARD -& MATING CONNECTOR TYPES ........................45 BIOS......................................... 47 12.01. MAIN....................................47 12.02. ADVANCED ..................................53 12.03. SECURITY ..................................98 12.04. BOOT ....................................101 12.05. MISC ....................................102 12.06. EXIT ....................................103 MITX-BDW-U (KTD-NO886-B) www.kontron.com // 3 - 104...
  • Page 5: 02/ User Information

    02.04. DISCLAIMER Kontron AG reserves the right to make changes without notice to any product, including circuits and/or software described or contained in this manual in order to improve design and/or performance. Specifications listed in this manual are subject to change without notice. Kontron AG assumes no...
  • Page 6: Warranty

    KONTRON AG TECHNICAL SUPPORT AND SERVICES If you have questions about installing or using your Kontron AG Product, then please notice that you will find many answers in this Users Guide. To obtain support please contact your local Distributor or Field Application Engineer (FAE).
  • Page 7 2. Driver Version numbers (Graphics, Network, and Audio). 3. Attached Hardware: Harddisks, CD-Rom, LCD Panels etc. If the Kontron Technology product seems to be defect and you want to return it for repair, please follow the guide lines from the following page: http://kontron.com/services/rma-information/kontron-technology-a-s...
  • Page 8: 03/ Introduction

    INTRODUCTION This manual describes the mITX-BDW-U board made by Kontron AG. This board will also be denoted mITX-BDW-U within this Users Guide. The mITX-BDW-U board is based on the BDW-U chipset, support 5 generation Intel® Broadwell i7 -, i5 -, i3 2Core mobile processors.
  • Page 9: 04/ Installation Procedure

    04.01. INSTALLING THE BOARD To get the board running follow these steps. If the board shipped from Kontron has already components like RAM and CPU cooler mounted, then relevant steps below can be skipped. 1. Turn off the PSU (Power Supply Unit)
  • Page 10 PCB and cause short circuits. 04.02. Take care when designing chassis interface connectors in order to fulfil the IEC60950 standard. Users of mITX-BDW-U (T4006) must evaluate the end-product to ensure compliance the requirements of the 60950-1 safety standard are met: ...
  • Page 11 Paristo voi räjähtää, jos se on virheellisesti samma batterityp eller en ekvivalent typ som asennettu. Vaihda paristo ainoastaan lalteval- rekommenderas av apparattillverkaren. Kassera mistajan suosittelemaan tyyppiln. Hävitä käytetty använt batteri enligt fabrikantens instruktion. paristo valmistajan ohjeiden mukaisesti. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 10 - 104...
  • Page 12: System Specifications

    05.01. COMPONENT MAIN DATA The table below summarizes the features of the mITX-BDW-U embedded motherboard. mITX-BDW-U: miniITX (170.18 mm by 170.18 mm), Height approx. 23 mm from top of FORM FACTOR PCB board. On board CPU variants Support 5th Generation Intel® Core™ (Broadwell-U Mobile) PROCESSOR processors on a BGA 1168 in a Multi-chip package with the PCH (max.
  • Page 13 Current draw is less than 4.2µA when PSU is disconnected and 0 µA in S0 – S5. CAUTION: Danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 12 - 104...
  • Page 14  Kontron Technology / Phoenix BIOS (EFI core version) BIOS  Support for ACPI 4.0 ( Advanced Configuration and Power Interface), Plug & Play  Suspend (S1 mode)  Suspend To Ram (S3 mode)  Suspend To Disk (S4 mode) ...
  • Page 15: Mitx-Bdw-U Block Diagram

     5th generation Intel® Core™ i3 processor The BGA CPU is premounted from factory. Kontron has defined the board versions as listed in the following table, so far all based on Embedded CPUs. Later other versions are expected. MITX-BDW-U (KTD-NO886-B) www.kontron.com...
  • Page 16: System Memory Support

    The mITX-BDW-U is delivered with premounted heatsink: 05.04. SYSTEM MEMORY SUPPORT The mITX-BDW-U has two DDR3L SO-DIMM sockets. The sockets support the following memory features:  2x DDR3L 1.35 V SO-DIMM 204-pin ...
  • Page 17: Mitx-Bdw-U Graphics Subsystem

    05.05. mITX-BDW-U GRAPHICS SUBSYSTEM The mITX-BDW-U equipped with Intel ® i3, i5 or i7 processor, supports Intel ® Gen 8 HD Graphics core. All mITX-BDW-U versions support three displays pipes. The DP interface supports the DisplayPort 1.2a specification. The PCH supports High-bandwidth Digital Content Protection for high definition content playback over digital interfaces.
  • Page 18: Power Consumption

    In order to ensure safe operation of the board, the input power supply must monitor the supply voltage and shut down if the supply is out of range – refer to the actual power supply specification. Please note, MITX-BDW-U (KTD-NO886-B) www.kontron.com...
  • Page 19 In some cases, this can lead to compatibility problems with ATX power supplies, which require a minimum load to stay in regulation. The mITX-BDW-U board must be powered through either the ATX+12V-4p (4-pole) connector using standard ATX power supply or by an external 19V power adapter through the Rear I/O power jack.
  • Page 20 CURRENT DRAW / [MA] POWER CONSUMPTION / [W] +12 V 0.9102 +19 V 0.9102 TOTAL* WINDOWS 7 – S5 (SHUTDOWN) SUPPLY CURRENT DRAW / [MA] POWER CONSUMPTION / [W] +12 V 0.824 +19 V 0.824 TOTAL* MITX-BDW-U (KTD-NO886-B) www.kontron.com // 19 - 104...
  • Page 21 SUPPLY CURRENT DRAW / [MA] POWER CONSUMPTION / [W] +12 V 1.475 +19 V TOTAL* WINDOWS 7 – S5 (SHUTDOWN) SUPPLY CURRENT DRAW / [MA] POWER CONSUMPTION / [W] +12 V 78.87 0.969 MITX-BDW-U (KTD-NO886-B) www.kontron.com // 20 - 104...
  • Page 22 +19 V 0.969 TOTAL* MITX-BDW-U (KTD-NO886-B) www.kontron.com // 21 - 104...
  • Page 23: 06/ Connector Locations

    CONNECTOR LOCATIONS 06.01. mITX-BDW-U - FRONTSIDE MITX-BDW-U (KTD-NO886-B) www.kontron.com // 22 - 104...
  • Page 24: 07/ Connector Definition

    On-board pull-up or pull-down resistors on input pins or open-collector output pins. Note Special remarks concerning the signal. The abbreviation TBD is used for specifications which are not available yet or which are not sufficiently specified by the component vendors. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 23 - 104...
  • Page 25: 08/ Io-Area Connectors

    AUX (+) channel used by DP DDC Clk used by HDMI Aux Ch (n) Aux Channel (-) or DDC Data AUX (-) channel used by DP DDC Data used by HDMI Hot Plug Internally pull down (100 Kohm). MITX-BDW-U (KTD-NO886-B) www.kontron.com // 24 - 104...
  • Page 26: Ethernet Connectors (J4 & J5)

    Fused by 1.5 A resetable PTC fuse. 08.02. ETHERNET CONNECTORS (J4 & J5) The mITX-BDW-U supports two channels of 10/100/1000 Mbit Ethernet, one (LAN1) is based on Intel® Clarkville i218LM Gigabit PHY and one other controller (LAN2) are based on Intel® Pearsonville i211AT PCI Express controller.
  • Page 27: Usb Connectors (Io Area)

    08.03. USB CONNECTORS (IO AREA) The mITX-BDW-U board contains a EHCI (Enhanced Host Controller Interface) and a XHCI (Extensible Host Controller Interface). The EHCI controller supports six USB 2.0 ports allowing data transfers up to 480 Mb/s. The XHCI controller supports up to four USB 3.0 ports allowing data transfers up to 5Gb/s. Four of the USB 3.0 ports are shared with four of the USB 2.0 ports (USB0 –...
  • Page 28 For USB3.0 cabling it is required to use only HiSpeed USB cable, specified in USB3.0 standard: USB Connector J6 & J7 (USB0, 1, 2 & 3) The dual USB connectors J6 & J7, Ports 0, 1, 2 and 3 supports USB3.0/USB2.0. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 27 - 104...
  • Page 29: Audio Jack Connectors (J1 & J2)

    ADCs. The Following Audio connector is available in IO Area. Audio Speakers, Line-in and Microphone are available in a stacked audiojack connector: SIGNAL TYPE NOTE LINE1-IN-L 1.0 V 30 kΩ RMS, RING LINE1-IN-R 1.0 V , 30 kΩ SLEEVE MITX-BDW-U (KTD-NO886-B) www.kontron.com // 28 - 104...
  • Page 30 SIGNAL DESCRIPTION NOTE LINE1-IN-L Line In signal Left LINE1-IN-R Line In signal Right OUT-L Speaker Out Left Shared with J34 pin header connector OUT-R Speaker Out Right Shared with J34 pin header connector MITX-BDW-U (KTD-NO886-B) www.kontron.com // 29 - 104...
  • Page 31: 09/ Internal Connectors

    INTERNAL CONNECTORS 09.01. DC POWER - ATX CONNECTOR (INT12V - J10) The mITX-BDW-U boards are designed to be supplied from either a 12 V ATX-style power supply or an external 19 V power adapter. ATX+12 V-4p Power Connector (J10): NOTE...
  • Page 32: Ps/2 Keyboard And Mouse Connector (Kbdmse) (J15)

    1.1 A resettable fuse. Note: The PS/2 connector does not support wake functions. SIGNAL TYPE IOH/IOL PULL U/D NOTE KBDCLK /14 mA KBDDAT /14 mA MSCLK /14 mA MSDAT /14 mA 5 V/SB5 V MITX-BDW-U (KTD-NO886-B) www.kontron.com // 31 - 104...
  • Page 33: Sata (Serial Ata) Disk Interface

    09.05. SATA (SERIAL ATA) DISK INTERFACE The mITX-BDW-U has an integrated SATA Host controller (PCH in the BDW-U chipset) that supports independent DMA operation on two ports. One device can be installed on each port for a maximum of two SATA devices via two SATA connectors and one M.2 connector.
  • Page 34 SATA* RX+ / RX- Host transmitter differential signal pair SATA* TX+ / TX- Host receiver differential signal pair “*” specifies 0 or 1 depending on SATA port. Available cable kit: PN 821035 Cable SATA 500 mm MITX-BDW-U (KTD-NO886-B) www.kontron.com // 33 - 104...
  • Page 35: Usb Connectors (Internal)

    16/20/24-bit S/PDIF TX Outputs supporting 48 K/96 K/44.1 K/88.2 KHz sample rate HEADER SIGNAL TYPE SPDIF_OUT O-3.3 09.09. FRONT PANEL CONNECTOR (FRONTPNL) (J23) PULL IOH/ PULL IOH/IOL TYPE SIGNAL SIGNAL TYPE NOTE NOTE USB8_5 V USB9_5 V USB8- USB9- MITX-BDW-U (KTD-NO886-B) www.kontron.com // 34 - 104...
  • Page 36 The reset process continues even though the Reset Input is kept low. LINE2 Line2 is second stereo Line signals MIC2 MIC2 is second stereo microphone input. SB3V3 Standby 3.3 V voltage AGND Analogue Ground for Audio MITX-BDW-U (KTD-NO886-B) www.kontron.com // 35 - 104...
  • Page 37: Serial Com1 - Com2 Ports (J21, J25)

    PN 821042 Cable Front Panel Open-End, 300 mm 09.10. SERIAL COM1 – COM2 PORTS (J21, J25) Two RS232 serial ports are available on the mITX-BDW-U. The typical definition of the signals in the COM ports is as follows: SIGNAL DESCRIPTION Transmitted Data, sends data to the communications link.
  • Page 38: Lvds Flat Panel Connector (J33)

    Max. 0.5 A LVDS LVDS B0- LVDS B0+ LVDS LVDS LVDS B1- LVDS B1+ LVDS LVDS LVDS B2- LVDS B2+ LVDS LVDS LVDS BCLK- LVDS BCLK+ LVDS LVDS LVDS B3- LVDS B3+ LVDS MITX-BDW-U (KTD-NO886-B) www.kontron.com // 37 - 104...
  • Page 39: Feature Connector (J28)

    Max. 0.5 A Note: The mITX-BDW-U on-board LVDS connector supports single and dual channel, 18/24 bit SPWG panels up to a resolution of 1600x1200 or 1920x1080 and with limited frame rate up to 1920x1200. Signal Description – LVDS Flat Panel Connector:...
  • Page 40 EGAD TMA0 +12 V TOUCH_I2C TOUCH_I2C -1K/ _CLK _DAT 25/25 Notes: 1 . Pull-up to +3V3Dual (+3V3 or SB3V3). . Pull-up to on-board Battery. . Pull-up to +3V3. . Pull- up to SB3V3. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 39 - 104...
  • Page 41 Diode to 3V3 and has multiplexed functionality. Some pins can be DAC (Digital to Analogue Converter output), PWM (Pulse Width Modulated signal output), ADC (Analogue to Digital Converter input), TMRI (Timer Counter Input), WUI (Wake Up Input), RI (Ring Indicator Input) or some special function. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 40 - 104...
  • Page 42 RI1#/WUI0/GPD0 IS/IS/IOS GPIO14 RI2#/WUI1/GPD1 IS/IS/IOS GPIO15 TMRI0/WUI2/GPC4 IS/IS/IOS GPIO16 TMRI1/WUI3/GPC6 IS/IS/IOS GPIO17 L80HLAT/BAO/WUI24/GPE0 O4/O4/IS/IOS Available cable kit and Break-Out-Board: PN 820978 Feature BOB (Break-Out-Board) PN 1052-5885 Cable, Feature 44pol 1 to1, 300 mm MITX-BDW-U (KTD-NO886-B) www.kontron.com // 41 - 104...
  • Page 43: Load Default Bios Settings" Jumper (Jp1)

    ISOLATE# programming the SPI flash. Power Supply to the Motherboard must be turned off when loading SPI flash. The pull up resistor is connected via diode to 5VSB. MISO Master Input, Slave Output MITX-BDW-U (KTD-NO886-B) www.kontron.com // 42 - 104...
  • Page 44: Lpc Connector (J31)

    PULL PULL NOTE IOH/IOL TYPE SIGNAL SIGNAL TYPE IOH/IOL NOTE LPC CLK FRAME +5 V RST# LPC AD3 LPC AD2 +3V3 LPC AD1 LPC AD0 SMB_CL SMB_DAT SB3V3 SERIRQ CLKRUN# SUS_ST TPM_DRQ MITX-BDW-U (KTD-NO886-B) www.kontron.com // 43 - 104...
  • Page 45: 10/ Slot Connectors (Minipcie)

    RST# SATA5_RXP +3V3 SATA5_RXN +1.5 V SMB_CLK SATA5_TXN SMB_DATA SATA5_TXP USB12N USB12P +3V3 +3V3 SATA_DET5# +1.5 V +3V3 Note 1: 10K ohm pull-up to 3V3. Note 2: 2K2 ohm pull-up to 3V3 Dual. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 44 - 104...
  • Page 46: 11/ On-Board -& Mating Connector Types

    ON-BOARD -& MATING CONNECTOR TYPES The Mating connectors / Cables are connectors or cable kits which are fitting the On-board connector. The Kontron cable kits marked with “*” are included in the “mITX-BDW-U Cable & Driver Kit” PN 826603. ON-BOARD CONNECTORS...
  • Page 47 Please also notice that standard connectors like DP, miniPCIe, Audio Jack, Ethernet and USB are not included in the list. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 46 - 104...
  • Page 48: 12/ Bios

    12.01. MAIN Sub Menu available. White text for actual selected function which can be modified. Blue text for functions (not all can be modified). Black background for actual selection. Black text actual settings. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 47 - 104...
  • Page 49 FEATURE OPTIONS DESCRIPTION System Date MM/DD/YYYY Set the system date. System Time HH:MM:SS Set the system time. The following table describes the changeable settings: System Information MITX-BDW-U (KTD-NO886-B) www.kontron.com // 48 - 104...
  • Page 50 If you select ‘Enabled’ the diagnostic splash screen always Disabled displays during boot. If you select ‘Disabled’ the diagnostic Diagnostic Splash Screen splash screen does not display unless you press HOTKEY Enabled during boot. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 49 - 104...
  • Page 51 UEFI First Boot Priority Select priority of boot option between UEFI and Legacy. Legacy First Note 1 : Use either digit keys to enter value (0 – 99) or +/- keys to increase/decrease value. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 50 - 104...
  • Page 52 Set the priority of UEFI PXE Boot (Note 2) IPv4 First Note 1 : To use legacy PXE boot support, disable this option. Note 2 : Only visible if Network Stack is enabled. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 51 - 104...
  • Page 53 Error Manager FUNCTION SELECTION DESCRIPTION View Error Manager Log Enter Display Error Manager Log information. Clear Error Manager Log Enter Clear Error Manager Log. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 52 - 104...
  • Page 54: Advanced

    In order to make a selection of a submenu activated the ↑↓ keys until the requested submenu becomes white color, then activate the <Enter>. FUNCTION SELECTION DESCRIPTION English Select Language Select Language. Francais Etc. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 53 - 104...
  • Page 55 Silicon Information MITX-BDW-U (KTD-NO886-B) www.kontron.com // 54 - 104...
  • Page 56 EMA Support environment. Enabled Disabled Valid only for ACPI. Controls the Mobile East Fork feature MEF Support support in an ACPI environment. Enabled Disabled Enable/Disable Power and Temperature Instrumentation Enabled PTID Details. Enabled MITX-BDW-U (KTD-NO886-B) www.kontron.com // 55 - 104...
  • Page 57 Enable/Disable ACPI runtime D3 support. Disabled Note: to support RTD3, there must be hardware related Runtime D3 Support Enabled design to control devices powered by software. A custom BIOS configuration may be needed. Processor Configuration MITX-BDW-U (KTD-NO886-B) www.kontron.com // 56 - 104...
  • Page 58 Enable or disable MLC Streamer Prefetcher. Prefetcher Enabled Disabled Intel ® Spatial Prefetcher Enable or disable MLC Spatial Prefetcher Enabled Disabled MP MWAIT/Cx State Support Enabled Disabled BIOS Guard Enable/Disable BIOS Guard feature. Enabled MITX-BDW-U (KTD-NO886-B) www.kontron.com // 57 - 104...
  • Page 59: Processor Power Management

    Processor Power Management MITX-BDW-U (KTD-NO886-B) www.kontron.com // 58 - 104...
  • Page 60 Power Limit 1) in Watts. The value may vary from Long Power Limit 0, 1,2,…200 0 to Fused Value. If the value is 0, the fused value will be programmed. A value greater than fused TDP value will not be programmed. Continue MITX-BDW-U (KTD-NO886-B) www.kontron.com // 59 - 104...
  • Page 61 Disabled cTDP can still work. Disabled Lock TDP in Lock TDP Setting MSR_CONFIG_TDP_CONTROL Enabled Enables CTPD control via Disabled CTPD BIOS control runtime ACPI BIOS methods. This Enabled “Bios only” feature does not MITX-BDW-U (KTD-NO886-B) www.kontron.com // 60 - 104...
  • Page 62 C1 and C3 Disabled Enable/Disable Package C State Package C State Demotion Demotion. Enabled Disabled Enable/Disable Package C State Package C State UnDemotion UnDemotion. Enabled Disabled Enable/Disable C State Pre- C State Pre-Wake Wake. Enabled MITX-BDW-U (KTD-NO886-B) www.kontron.com // 61 - 104...
  • Page 63 Enable/Disable SATA Device. Enabled Select the SATA controllers Interface Combination AHCI operation mode. RAID Serial ATA Port x (Device if installed) (x = 0 – 3) Disabled Port Enable Enable/Disable this port. Enabled MITX-BDW-U (KTD-NO886-B) www.kontron.com // 62 - 104...
  • Page 64 Solid State Drive to this SATA port. Disabled DevSlp RTD3 Device Sleep Support Enabled Disabled Enable/Disable Device Sleep Idle DITO Configuration Timeout Configuration. Enabled DITO Value DITO Multiplier Value Software Feature Mask Configuration MITX-BDW-U (KTD-NO886-B) www.kontron.com // 63 - 104...
  • Page 65 OS. Enabled Memory Configuartion FUNCTION SELECTION DESCRIPTION Auto 1067 1333 1600 Maximum Memory Frequency Memory Frequency Limiter Selections in Mhz. 1867 2133 2400 2667 MITX-BDW-U (KTD-NO886-B) www.kontron.com // 64 - 104...
  • Page 66 Enable or disable DIMMs on Channel B. Disabled Enable/Disable Memory Remap Memory Remap above 4GB. Enabled Enable/Disable MRC FastBoot. Disabled Generally, this option only takes MRC FastBoot effect when doing cold Enabled boots/resets. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 65 - 104...
  • Page 67 Enable/Disable Cpu Audio Cpu Audio Device (D0:D3:F0) Device. Enabled Disabled CHAP Device (D0:D7:F0) Enable/Disable SA CHAP Device. Enabled Disabled Enable/Disable SA Thermal Thermal Device (D0:D4:F0) Device. Enabled Disabled CRID support Enable Compatible Revision ID. Enabled MITX-BDW-U (KTD-NO886-B) www.kontron.com // 66 - 104...
  • Page 68 Active State Power Management on SA side of the DMI Link. L0S And L1 Auto Disabled Enable/Disable DMI Extend Sync DMI Extended Sync control. Enabled Disabled Enable/Disable DMI Gen2 DMI Gen2 Support Control Support Control. Enabled MITX-BDW-U (KTD-NO886-B) www.kontron.com // 67 - 104...
  • Page 69 Enable/Disable Intel® VT for Directed I/O (VT-d) by reporting Disabled Intel® VT for Directed I/O (VT-d) the I/O device assignment to Enabled VMM through DMAR ACPI Tables. Disabled Enable/Disable X2APIC Opt Out X2APIC_OPT_OUT bit. Enabled MITX-BDW-U (KTD-NO886-B) www.kontron.com // 68 - 104...
  • Page 70 1 MByte GTT Size Gtt Memory Size of IGD. 2 MByte 128 MByte Aperture Size 256 MByte Graphics Aperture Size. 512 MByte Select Pre-Allocated Graphics DVMT Pre-Allocated 32 MByte Memory size used by the MITX-BDW-U (KTD-NO886-B) www.kontron.com // 69 - 104...
  • Page 71 Gfx Low Power Mode Mode. Enabled IGD Configuration FUNCTION SELECTION DESCRIPTION VBIOS Default Select the Video Device activated during POST. This has IGD – Boot Type no effect if external graphics are EFP3 present. EFP2 LFP2 MITX-BDW-U (KTD-NO886-B) www.kontron.com // 70 - 104...
  • Page 72 Software: Spread is controlled Software by BIOS. No LVDS Select the Active LFP IGD – Active LFP eDP Port-A Configuration. eDP Port-D 18 Bit Select the LFP Panel Color Panel Color Depth Depth. 24 Bit MITX-BDW-U (KTD-NO886-B) www.kontron.com // 71 - 104...
  • Page 73 PEG2 – Gen X Configure PEG2 B0:D1:F2 Speed. Gen2 Gen3 Enable/Disable the entry to C7 state [Run-time control] . Don’t Enabled Run-time C7 Allowed enable this feature until you Disabled have all the appropriate Save/Restore MITX-BDW-U (KTD-NO886-B) www.kontron.com // 72 - 104...
  • Page 74 PEG endpoint(s) during Enabled margin search, if needed. PEG Gen3 Preset Search dwell Preset Search Dwell Time 0, …1000, …65535 time in [ms]. Timing Start Margin 4, …15, …255 The starting value [4…255] for MITX-BDW-U (KTD-NO886-B) www.kontron.com // 73 - 104...
  • Page 75 Enable to generate BDAT PCIe Generate BDAT PEG Margin Data margin tables Enabled South Bridge Configuration FUNCTION SELECTION DESCRIPTION Disabled SMBUS Device Enable/Disable SMBUS Device. Enabled Port 80h Cycles LPC Bus Control where the Port 80h MITX-BDW-U (KTD-NO886-B) www.kontron.com // 74 - 104...
  • Page 76 Wake From DeepSx by the GP27 Wake From DeepSx assertion of GP27 pin. Enabled Specify what state to switch to State S5 State After G3 when power is re-applied after a State S0 power failure (G3 state). MITX-BDW-U (KTD-NO886-B) www.kontron.com // 75 - 104...
  • Page 77 Power Management of the DMI Link. L0S And L1 Auto Disabled The control of Extended Sync on DMI Link Extended Synch Control SB side of the DMI Link. Enabled PCI Express port assigned to LAN MITX-BDW-U (KTD-NO886-B) www.kontron.com // 76 - 104...
  • Page 78 Control PCIe Active State Power ASPM Management settings. L0S And L1 Auto Disabled L1.1 L1 Substates PCI Express L1 Substates setting. L1.2 L1.1 & L1.2 PCI Express Hot Plug HOT PLUG Disabled Enabled/Disabled. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 77 - 104...
  • Page 79 Enabled Enabled/Disabled. Root PCI Express System Error Disabled SECE on Correctable Error Enabled Enabled/Disabled. Disabled Root PCI Express PME Interrupt PME Interrupt Enabled/Disabled. Enabled Disabled PCI Express PME SCI PME SCI Enabled/Disabled. Enabled MITX-BDW-U (KTD-NO886-B) www.kontron.com // 78 - 104...
  • Page 80 This allows the use of USB 3.0 devices prior to OS boot. Note, this mode switch requires special OS driver support for USB 3.0 and USB 3.0 software available in the pre-boot environment. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 79 - 104...
  • Page 81 SB Azalia Configuration FUNCTION SELECTION DESCRIPTION Disabled Control Detection of the Azalia Azalia device. Auto Disabled Enable/Disable Docking Support Azalia Docking Support Enable for Azalia. Enabled Disabled Azalia PME Enabled Enable/Disable PME for Azalia. Enabled MITX-BDW-U (KTD-NO886-B) www.kontron.com // 80 - 104...
  • Page 82 In Serial IRQ Mode “Continuous” it is active all the Continuous time. 4 Frames The number of start frames at Start frames 6 Frames the beginning of the serial IRQ. 8 Frames MITX-BDW-U (KTD-NO886-B) www.kontron.com // 81 - 104...
  • Page 83 BIOS Lock Lock Enable feature. The whole Enabled BIOS region is not writable. Enable/Disable SMM LOCK Disabled feature. It will lock the SMRAM SMM LOCK and unable load SMM driver any Enabled more. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 82 - 104...
  • Page 84 SB Serial IO Config MITX-BDW-U (KTD-NO886-B) www.kontron.com // 83 - 104...
  • Page 85 I2C0 host controller. Enabled 3.3 V Use 1.8v for I2C0 devices listed SerialIo I2C0 Voltage below. 1.8 V Disabled USB Sensor SerialIo I2C0 Sensor Hub Intel Please Select Sensor Hub Kalapana Beach Sensor MITX-BDW-U (KTD-NO886-B) www.kontron.com // 84 - 104...
  • Page 86 SerialIo I2C1 ALPS TouchPad Sensor. Enabled Disabled Enables/Disables the Vendor SerialIo I2C1 Cypress TouchPad Sensor. Enabled Disabled Overrides the I2C1 Controller I2C1 Parameters Override Parameters Enabled Disabled SerialIo SPI0 SPIO host controller. Enabled MITX-BDW-U (KTD-NO886-B) www.kontron.com // 85 - 104...
  • Page 87 PXE boot. With PXE boot Enable or disable integrated LAN Disabled to wake the system. (The Wake Wake on LAN On LAN cannot be disabled if ME Enabled is on at Sx state). MITX-BDW-U (KTD-NO886-B) www.kontron.com // 86 - 104...
  • Page 88 OneWire @ GPIO16 Disabled = Full speed. Thermal: does regulate fan Disabled Fan Cruise Control (Note 2) speed according to specified Thermal temperature. Speed Speed: does regulate according to specified RPM. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 87 - 104...
  • Page 89 Seconds, use digit keys to enter value. Value 0 means Watchdog is disabled. Refer to “KT-API-V2 User Manual” to control the Watchdog via API or refer to “KT-API-V2 User Manual DLL” how to control Watchdog via Windows DLL. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 88 - 104...
  • Page 90 FUNCTION SELECTION DESCRIPTION Disabled Event Log Enable/Disable Event Log. Enabled Mark SMBIOS events as read. Mark SMBIOS as read Enter Marked SMBIOS events won’t be displayed. Clears SMBIOS events Enter Clears SMBIOS events. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 89 - 104...
  • Page 91 MDES for BIOS Service for BIOS events. Enabled Enable/Disable Intel ® ME Disabled ME IFR Feature Independent Firmware Enabled Recovery. Enables or disables the Disabled Firmware TPM Feature Firmware TPM present in the Enabled MITX-BDW-U (KTD-NO886-B) www.kontron.com // 90 - 104...
  • Page 92: Thermal Configuration

    Thermal Configuration MITX-BDW-U (KTD-NO886-B) www.kontron.com // 91 - 104...
  • Page 93 PROCHOT# OUT can be Enabled disabled selectively. Disabled Enable/Disable PROCHOT PROCHOT# Response Response. Enabled Disabled Enable/Disable VR Thermal Disable VR Thermal Alert Alert. Enabled Enable/Disable ACPI 3.0 T- ACPI 3.0 T-States Disabled States. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 92 - 104...
  • Page 94 This value controls the temperature of the ACPI Active Disabled Active Trip Point Lo Fan Trip Point – the point where the 15, 23, …55, …119 OS turns the processor fan on low. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 93 - 104...
  • Page 95 Use “+” and “-“ keys to change value. Disabled Thermal Sensor Device Enable Enable Thermal Sensor Device. Enabled Enable/Disable ME SMBus Disabled ME SMBus Thermal Reporting Thermal Reporting Enabled Configuration. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 94 - 104...
  • Page 96 None: Change will not apply. Permanently: Changes will be None Apply ICC settings after reboot applied permanently, starting Permanently after reboot after the next reboot. Use it to provide changes that are verified and safe. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 95 - 104...
  • Page 97 New SSC spread percent base frequency. Allowed range 0, 1, …, 50 is limited by Max supported SSC [0.01 %] %. Changes will not be applied unless ‘Apply settings’ is pressed. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 96 - 104...
  • Page 98 Intel® Smart Connect Technology FUNCTION SELECTION DESCRIPTION Disabled ISCT Configured Enable ISCT Enabled MITX-BDW-U (KTD-NO886-B) www.kontron.com // 97 - 104...
  • Page 99: Security

    Press Enter to type User Hint User Hint String (Note1) (up to 20 characters) String. Set the minimum number of Min. password length 1, 2, …, 20 characters for password (1-20). Authenticate User on Boot Disabled Enable/Disable User MITX-BDW-U (KTD-NO886-B) www.kontron.com // 98 - 104...
  • Page 100 Enable or disable secure boot Secure Boot Option function. Enabled Reset secure boot variables to Reset to Defaults Enter manufacturing defaults. PK will be deleted, the platform Change to Customization Enter will be changed to setup mode, MITX-BDW-U (KTD-NO886-B) www.kontron.com // 99 - 104...
  • Page 101 TPM Action TPM actions require TPM to be Enabled to take effect. Disable and Deactivate Set Owner Install, with State=True Set Owner Install, with State=False Enable, Activate, and Set Owner Install, with State=True MITX-BDW-U (KTD-NO886-B) www.kontron.com // 100 - 104...
  • Page 102: Boot

    Do not require PP for clear Enable, Activate, and Clear Enable, Activate, Clear, Enable, and Activate Enabling this option causes the Disabled TPM Support system to omit recording boot Enabled device attempts in PCR[4]. 12.04. BOOT MITX-BDW-U (KTD-NO886-B) www.kontron.com // 101 - 104...
  • Page 103: Misc

    Select ►Su↓-Menu Exit Select Menu Enter Save and Exit Note: This menu contains dynamic driver settings and possibly other settings. Don’t change these settings. This menu might be removed in future BIOS version. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 102 - 104...
  • Page 104: Exit

    Load the original value of this Discard Changes boot time. Not the default Setup Discard Changes value. Save all changes of all menus, Save Changes Save Changes but do not reset system. MITX-BDW-U (KTD-NO886-B) www.kontron.com // 103 - 104...
  • Page 105 Kontron is a listed company. Its shares are traded in the Prime Standard segment of the Frankfurt Stock Exchange and on other exchanges under the symbol “KBC”. For more information, please visit: www.kontron.com...
  • Page 106 Our company network supports you worldwide with offices in Germany, Austria, Switzerland, Great Britain and the USA. For more information please contact: FORTEC Elektronik AG FORTEC Elektronik AG Hauptniederlassung Büro West Lechwiesenstr. 9 Hohenstaufenring 55 86899 Landsberg am Lech 50674 Köln Telefon: +49 (0) 8191 91172-0 Telefon:...

Table of Contents