Operation displays

The operation displays appear at the bottom of the screen for approx. 4 seconds when any of the following operations have been performed
with the operation panel of the ROP.
● Master gain change
● Electronic shutter change
● Lens extender change
● Scene file change
● REF LOAD is changed
● FILTER is changed
The display time can be changed from [MAINTENANCE] menu > [PM OPERATION STATUS] > [STATUS DISP TIME].
Item
MASTER GAIN
SHUTTER
LENS EXT
SCENE FILE
REF LOAD
FILTER
MASTER GAIN 12 dB
Display range
Setting values on
The master gain value is displayed here.
camera
● For the setting values, refer to the Operating Instructions for the camera.
Setting values on
The speed of the electronic shutter is displayed here.
camera
● For the setting values, refer to the Operating Instructions for the camera.
1.0
The magnification of the lens extender is displayed here.
2.0
● When the magnification of the lens extender is set to 2x, [2.0] is
displayed. Otherwise, [1.0] is displayed.
OFF
This indicates the scene file name.
1 to 8
FACTORY
This indicates the reference file that was loaded via reference call recalling.
USER1 to USER3
REF1 to 3
****
The names of the ND filter/CC filters are displayed here.
(ND/CC filter name)
- 38 -