Daikin RDT-135c Installation And Maintenance Manual page 66

Roofpak series singlezone roof mounted heating and cooling units
Table of Contents

Advertisement

Wiring Diagrams: Legend
ID
Description
RAE
Return air enthalpy sensor
RAT
Return air temperature sensor Return section
REC1
Receptacle, main box
REC2
Receptacle, condenser box
REC3
Receptacle, field power, 115V Discharge bulkhead
REC10–
Receptacle, cabinet sections
23
S1
Switch, system on/off
S2
Switch, system on/off,
condenser unit
S3
Switch, furnace on/off
S4
Switch, inverter bypass, on/ off Main control box
S7
Switch, local on/auto/off to
controller
S10–23
Switches, cabinet section lights Cabinet sections
S40–45
Switches, door interlock, UV
lights
SC11
Speed control, circuit #1
SC21
Speed control, circuit #2
SD1
Smoke detector, supply
SD2
Smoke detector, return
SPS1, 2
Static pressure sensors, duct/
building
SR1-3
Sequencing relays, electric
heat
SV1, 2
Solenoid valves, liquid
SV5, 6
Solenoid valves, hot gas
SV61, 62 Solenoid valves, sump, fill
SV63
Solenoid valves, sump, drain
SWT
Sump water temperature
sensor
T1
Transformer, main control (line/
115VAC)
T2
Transformer, control input (115/
24VAC)
T3
Transformer, control output
(115/24VAC)
T4
Transformer, exh. damper
actuator (115/12VDC)
T5
Transformer, electirc heat
T6
Transformer, dew point
controlller (115/24VAC)
T9
Transformer, refrig. circuit 24V Main control box
T11
Transformer, speedtrol (line/
240VAC)
TB1
Terminal block, internal
TB2
Terminal block, field
TB3
Terminal blocks, factory
TB4
Terminal block, RFS, field
TB5
Terminal block, RCS, field
TB6
Terminal block, RCS, factory
TB7
Terminal block, 115V
convenience outlet, field
TB8
Terminal block, 115V conv.
outlet, RCS, field
TB11
Terminal block, heat
TB23
Terminal block, oil pressure
box, RPE/RCE only
TB25, 26,
Terminal block, split unit
27, 28
junction box
TC12, 13,
Temperature controls, Fantrol Condenser section
14
64
Standard location
Return section
Main control box
Condenser control box
Cabinet sections
Main control box
Condenser control box
Gas heat box
Main control box
Cabinet sections
Condenser bulkhead
Condenser bulkhead
Discharge section
Return section
Main control box
Electric heat box
Condenser section
Condenser section
Main/RCE control box
Main/RCE control box
Evap. condenser section
Main control box
Main control box
Main control box
Main control box
Electric heat box
Main control box
Condenser section
Main control box
Main control box
Main control box
Main control box
Condenser control box
Condenser control box
Main control box
Condenser control box
Heat control box
Evap. condenser vestibule
Junction box, split unit
ID
Description
TC56
Temperature control, water
pipe heater
TC66
Temperature control, vestibule
exhaust fan
TD1, 2
Time delay, compressor
lockout
TD3, 4
Time delay, hi-pressure
TD5–8
Time delay, part winding,
compr #1 - 4
TD10
Time delay, hi turn down burner Gas heat box
TD11, 12 Time delay, low ambient
TR1, 2
Transducer, pressure
U1, 2
Unloaders, compressors
UV
Ultra-violet light(s)
VM1
Valve motor #1, heating
VM5
Valve motor #5, cooling
VV1
Vent valve, gas heat
WL63
Water level, sump, fill
WL64
Water level, sump, low water
ZNT1
Zone temp. sensor, setback
General Notes
1.
2.
3.
4.
5.
6.
7.
200/ H200
8.
WN7
9.
Standard location
Evap. condenser vestibule
Evap. condenser vestibule
Main/cond. control box
Main/cond. control box
Main control box
Main/cond. control box
Main control box
On compressers
Coil/discharge section
Gas heat box/ heat section
Coil section, cool
Heat Section, Gas
Evap. condenser section
Evap. condenser section
Field installed
Field wiring
Factory wiring
Shielded wire/cable
Main control box
terminals
Auxilliary box
terminals
Field terminals
Plug connector
Wire/harness number
Wire nut/ID
IM 738-2