Daikin RDT-135c Installation And Maintenance Manual page 65

Roofpak series singlezone roof mounted heating and cooling units
Table of Contents

Advertisement

ID
Description
HTR1–6
Crankcase heaters
HTR65
Heater, sump
HTR66
Heater, vestibule
HUM1
Humidstat sensor
IT
Ignition transformer
LAT
Leaving air temperature sensor Energy recovery section
LP1, 2
Low-pressure controls,
refrigeration
LP5
Low-pressure control, gas
LR10
Line Reactor, supply fan
LR20
Line reactor, return/exhaust fan Inv. bypass/main cont. box
LS1, 2
Limit switch, low fire, high fire Gas heat box
LT10–23 Light, cabinet sections
M1–8
Contactor, compressor
M10
Contactor, supply fan
M11–18
Contactor, condenser fans,
circuit #1
M20
Contactor, return fan
M21–28
Contactor, Condenser fans,
circuit #2
M29
Contactor, burner motor
M30
Contactor, reversing, invertor
bypass, supply fan
M31–39
Contactor, electric heat (top
bank)
M40
Contactor, reversing, Invertor
Bypass, Return Fan
M41–50
Contactor, electric heat (bot.
bank)
M60
Contactor, energy recovery
wheel
M64
Contactor, sump pump
M65
Contactor, sump heater
MCB
Microprocessor circuit board
MJ
Mechanical Jumper
MMP1–8 Manual motor protector,
compressors
MMP10
Manual motor protector, supply
fan
MMP11–
Manual motor protector, cond.
18
fans, ckt#1
MMP20
Manual motor protector, return
fan
MMP21–
Manual motor protector, cond.
28
fans, ckt#2
MMP30
Manual motor protector, invrtr.
bypass, sup. fan
MMP40
Manual motor protector, invrtr.
bypass, ret. fan
MMP51,
Manual motor protector,
52, 53
exhaust fan(s)
MMP60
Manual motor protector,
energy recovery wheel
MMP64
Manual motor protector, sump
pump
MP1–6
Motor protector, compr.#1-6
OAE
Outside air enthalpy sensor
OAT
Outside air temperature sensor Economizer section
OP1–4
Oil pressure controls,
compr.#1-4
PB1, 2
Power block, power distribution Main control box
IM 738-2
Standard location
On compressers
Evap. condenser section
Evap. condenser vestibule
Energy recovery section
Gas heat box
On compressors
Heat section, gas
Inverter bypass box
Supply fan section
Main/cond. control box
Main control box
Main/cond. control box
Main control box
Main/cond. control box
Gas heat box
Inverter bypass box
Electric heat box
Inverter bypass box
Electric heat box
Main control box
Main/cond. control box
Main/cond. control box
Main control box
All control boxes
Main/cond. control box
Main control box
Main/cond. control box
Main control box
Main/cond. control box
Inverter bypass box
Inverter bypass box
Prop exhaust box
Main control box
Main/RCE control box
On compressors
Economizer section
Condenser section
ID
Description
PB3
Power block, power
distribution, electric heat
PB4
Power block, power
distribution, condenser
PB9, 10
Power block, supply fan
PB11, 12 Power block, power distribution Main control box
PB19, 20 Power block, return/exhaust
fan
PC5
Pressure control, clogged filter Pre filter section
PC6
Pressure control, clogged final
filter
PC7
Pressure control, proof airflow Supply fan section
PC8
Pressure control, minimum
airflow
PC12, 22 Pressure control, Fantrol
PM1
Phone modem
PS1, 2
Pumpdown switches, refrig
circuits
PS3
Pumpdown switch, RFS only
PVM1, 2 Phase voltage monitor
PVM4
Phase voltage monitor,
condenser
R1, 2
Relay, hi pressure reset
R3, 4
Relay, hi pressure delay
R5–8
Relay, safety, cool fail
R9, 10
Relay, compressor lockout
R11, 12
Relay, Speedtrol fan cycling
R20
Relay, Heat, gas/ steam/ hot
water
R21, 22
Relay, heat, gas (hi-turn down) Gas heat box
R23
Relay, heat, gas & electric
R24
Relay, heat alarm, gas
R25
Relay, heat, gas, start supply
fan inverter
R26
Relay, isol/exh. dampers,
open/close
R28
Relay, isolation damper, safety Main control box
R29
Relay, remote fire alarm
R30
Relay, cool valve with face
bypass
R45
Relay, UV lights
R46, 47
Relay, supply fan inverter, incr/
decr
R48, 49
Relay, return fan inverter, incr/
decr
R56
Relay, heater, water pipe
R58,59
Relay, heat wheel inverter, incr/
decr
R60
Relay, energy recovery
wheel,enable
R61
Relay, smoke detector,
discharge air
R62, 63,
Relay, use on specials
65
R64
Relay, sump pump
R66
Relay, smoke detector, return
air
R67
Relay, supply fan, enable
R68
Relay, return fan, enable
R69
Relay, Inv. bypass VAV box
interlock
R70–79
Relay, use on specials
Wiring Diagrams: Legend
Standard location
Electric heat box
Condenser control box
Junction box, split unit
Junction box, split unit
Final filter section
Coil section, cool
Condenser section
Main control box
Main/cond. control box
Main control box
Main control box
Condenser control box
Main/cond. control box
Main/cond. control box
Main/cond. control box
Main/cond. control box
Main/cond. control box
Gas heat/main cont. box
Gas/electric heat box
Main control box
Main control box
Main control box
Main control box
Main control box
Main control box
Main control box
Main control box
Main/RCE control box
Main control box
Main control box
Main control box
Main control box
Main/RCE control box
Main control box
Main control box
Main control box
Main control box
Main control box
63