Brocade Communications Systems FastIron GS Hardware Installation Manual page 39

Table of Contents

Advertisement

FIGURE 25
3
1
2
3
4
5
9. Connect the ground, positive, and negative wires as follows:
Brocade FastIron GS and FastIron GS-STK Hardware Installation Guide
53-1001783-01
DRAFT: BROCADE CONFIDENTIAL
DC Power Supply Connector
Negative terminal screw
Positive terminal screw
48 RTN lead
-48 VDC lead
10 AWG wire
Slip the 10 AWG ground wire into the opening under the negative (—) mark until the wire is
fully in place, then use the crimper to crimp the lug snugly onto the wire. Gently pull the lug
away from the wire to verify that the lug is securely fastened.
Connect the -48 VDC lead to the negative (—) terminal and tighten the negative terminal
screw.
Connect the 48 RTN lead to the positive (+) terminal and tighten the positive terminal
screw.
Figure 26
shows how to connect the wires on a DC power supply.
Installing a redundant power supply